background image

2

1.  Carefully unpack screen and remove outer wrapping from case.

2.  Do not remove black tape or rubber bands from slat pocket.

3.  Always handle screen in horizontal position.

Important Safety Instructions

When using your video equipment, basic safety precautions should always be followed, including the following:

1.  Read and understand all instructions before using.

2.  Maximum surrounding air temperature 122°F (50°C).

3.  Main disconnect must be incorporated in the fixed wiring in 

accordance with the wiring rules.

4.  Rated for indoor use only.

5.  Use copper rated conductors rated 167°F (75°C) or higher.

6.  If the supply cord is damaged, it must be replaced by the 

manufacturer, its service agent or similarly qualified persons in 
order to avoid hazard.

7.  Supplied drive is only intended for use in Da-Lite screen models 

Advantage, Contour, and Cosmopolitan.

8.  Position the cord so that it will not be tripped over, pulled, or 

contact hot surfaces.

9.  If an extension cord is necessary, a cord with a current rating at 

least equal to that of the appliance should be used. Cords rated 
for less amperage than the appliance may overheat.

10.  To reduce the risk of electric shock, do not disassemble this 

appliance. Contact an authorized service dealer when repair 
work is required. Incorrect reassembly can cause electric shock 
when the appliance is used subsequently.

11.  The use of an accessory attachment not recommended by the 

manufacturer may cause a risk of fire, electric shock, or injury to 
persons.

12.  Failure to provide adequate structural strength for this 

component can result in serious personal injury or damage to 
equipment! It is the installer’s responsibility to make sure the 
structure to which this component is attached can support the 
weight of all equipment. Reinforce the structure as required 
before installing the component.

13.  Use this projection screen only for its intended use as described 

in these instructions. Do not use attachments not recommended 
by the manufacturer.

Save These Instructions

Pre-Installation 

Original Instructions

Disclaimer

Milestone and its affiliated corporations and subsidiaries (collectively "Milestone"), intend to make this manual accurate and complete. 
However, Milestone makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide 
for every possible contingency in connection with the installation or use of this subject to change without notice or obligation of any 
kind. Milestone makes no representation of warranty, expressed or implied, regarding the information contained herein. Milestone 
assumes no responsibility for accuracy, completeness or sufficiency of the information contained in this document.

Da-Lite® is a registered trademark of Milestone AV Technologies. All rights reserved.

Summary of Contents for Cosmopolitan Electrol

Page 1: ...INSTRUCTION BOOK FOR Cosmopolitan Electrol For Sizes Up To 9 x 12 ...

Page 2: ... electric shock when the appliance is used subsequently 11 The use of an accessory attachment not recommended by the manufacturer may cause a risk of fire electric shock or injury to persons 12 Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this ...

Page 3: ...th 8 Length B is the distance between wall mounting holes at back of end caps and is the fabric width 6 1 2 4 4 Motor End A B Installation 3 8 Diameter For Ceiling Installation Enclosure Cover 7 8 Diameter Opening For Electrical Fittings Picture Surface 1 29 32 5 32 7 8 Diameter Knock Out 4 23 32 5 7 8 6 3 32 1 3 16 ...

Page 4: ...uban adhésif avec un couteau ou un outil tranchant Retirez à la main 3 Install electrical hook up that applies to your unit Make sure to review your Electrical Installation Checklists and wiring diagrams included for either 120 volt switch 220 240 volt switch or low voltage control 4 Test installation by running screen up and down a few times Be prepared to stop screen Standard Duty Cycle 1 MIN ON...

Page 5: ...ver tighten fasteners or damage may occur 3 Attach screen securely to studding or other solid surface never to plaster only 4 MAKE SURE SCREEN IS MOUNTED LEVEL Ceiling Mounting 1 Heavy screw hooks may be installed into wood joists Other types of hooks or chain may be used for other ceilings or for stage installations 2 Insert hooks or chain through proper openings provided in sides of end caps Scr...

Page 6: ...Off Common White Black With Yellow Up Red Rocker Switch AC Common 120 V 60 Hz 2 5 Max Amp Operating Switch And Plate Furnished With Screen SPDT With Center Off In Multiple Control Installations This Switch Is Replaced By The Low Voltage Control Operated From Push Button Stations To Junction Box Mounted In Screen Case In Which Internal Wiring Terminates In White Black and Red Leads Down White Limit...

Page 7: ... 24 gauge wire can be used in place of the supplied RJ 14 cable to connect the wall switch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 3 conductor connection tha...

Page 8: ...ing code Blue AC Common Brown AC Hot 230V AC 50Hz Green Yellow Ground Jumper Wire Green Yellow Ground Motor NOTE A single switch cannot be used to operate more than one screen In multiple control installations this switch is replaced by the low voltage control operated from push button stations Contact the factory for further information To Junction Box Mounted In Screen Case In Which Internal Wir...

Page 9: ...lack Orange Purple Brown 220V Wiring Diagram with Operation Limit Adjustment Wall Switch 3 conductor 20 24 gauge wire can be used in place of the supplied RJ 14 cable to connect the wall switch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party co...

Page 10: ...all switch is for operation only and CANNOT be used to make limit switch adjustments Therefore it is advised to wire the limit adjustment switch or provide a 3 conductor connection that is accessible Power Input 220VAC 50Hz Green Yellow Ground Blue Hot Brown Common Power Wire Data Cable RJ 45 Jack Black Down White Common Red Up Red Black White Inputs Output Black Down White L Common Red Up Push Do...

Page 11: ...or s screen trigger output polarity does not matter The red and black wires from the VPI are interchangeable IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 3 conductor connection that is accessible 3 conductor 20 24 gauge wire can be used in place of the supplied RJ...

Page 12: ...re drop than what was ordered At least 1 1 2 wraps of fabric must remain on the roller This screen comes standard with 0 or 2 black at the top See the specification data sheet for details ATTENTION N effectuez pas de réglage pour obtenir un déroulement supérieur à celui commandé Au moins 1 à 1 2 tour de toile doit être maintenu sur le cylindre Cet écran est doté de série d une bande noire supérieu...

Page 13: ...the wall switch over and use the up button on front of switch Press and hold until the desired travel position is reached If you travel to far up you can press the down to move the screen downward If you press and let go of either up or down button the motor will do a small jog in that direction for finer adjustment of screen Once desired position is reached turn switch over press and hold up tact...

Page 14: ... closure across the common up and down wires will be a stop command Up Dry Contact Down Dry Contact Common Both Bus Bus 5V Bus Operation of Screens With A Built In Low Voltage Control or VPI Operation Limit Adjustment Wall Switch 1 Press DOWN button on screen switch and screen will deploy out of case in downward direction 2 Press STOP button on screen switch and screen will stop if in movement 3 P...

Page 15: ...connect Defective motor limit switch or capacitor Replace motor assembly NOTE Motor is a sealed assembly Capacitor burned out Replace motor assembly Incorrect stopping position in downward direction Lost roller wrap See instructions below Down limit switch out of adjustment See installation instructions Incorrect stopping position in upward direction Lost roller wrap See instructions below Up limi...

Page 16: ...SE AND MERCHANTABILITY Any implied warranties of fitness for use or merchantability that may be mandated by statute or rule of law are limited to the one 1 year warranty period This warranty gives you specific legal rights and you may also have other rights which vary from state to state TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW NO LIABILITY IS ASSUMED FOR EXPENSES OR DAMAGES RESULTING FRO...