46832

LIMITED ONE YEAR WARRANTY ON DA-LITE PRESENTATION PRODUCTS

Milestone AV Technologies LLC warrants certain Da-Lite branded products to the original purchaser only, to be free from defects in 
materials and workmanship for a period of one (1) year from the date of purchase by the original purchaser; provided they are properly 
operated according to Da-Lite's instructions and are not damaged due to improper handling or treatment after shipment from the 
factory.

This warranty does not apply to equipment showing evidence of misuse, abuse or accidental damage, or which has been tampered 
with or repaired by a person other than authorized Da-Lite personnel.

Da-Lite’s sole obligation under this warranty shall be to repair or to replace (at Da-Lite’s option) the defective part of the merchandise. 
Returns for service should be made to your Da-Lite dealer. If it is necessary for the dealer to return the screen or part to Da-Lite, 
transportation expenses to and from Da-Lite are payable by the purchaser and Da-Lite is not responsible for damage in shipment.  
To protect yourself against damage or loss in transit, insure the product and prepay all transportation expenses.

TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS 
OR IMPLIED, INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANTABILITY.

 Any implied warranties of fitness for use, 

or merchantability, that may be mandated by statute or rule of law are limited to the one (1) year warranty period. This warranty gives 
you specific legal rights, and you may also have other rights, which vary from state-to-state. 

TO THE MAXIMUM EXTENT PERMITTED 

BY APPLICABLE LAW, NO LIABILITY IS ASSUMED FOR EXPENSES OR DAMAGES RESULTING FROM INTERRUPTION IN OPERATION 
OF EQUIPMENT, OR FOR INCIDENTAL, DIRECT, OR CONSEQUENTIAL DAMAGES OF ANY NATURE.

In the event that there is a defect in materials or workmanship of a Da-Lite product, you may contact our Customer Care Specialists at 
3100 North Detroit Street, Warsaw, IN 46582, (574) 267-8101, (800) 622-3737.

IMPORTANT: THIS WARRANTY SHALL NOT BE VALID AND DA-LITE BRANDED PRODUCTS SHALL NOT BE BOUND BY THIS 
WARRANTY IF THE PRODUCT IS NOT OPERATED IN ACCORDANCE WITH THE DA-LITE WRITTEN INSTRUCTIONS.

Keep your sales receipt to prove the date of purchase and your original ownership.

A BRAND OF MILESTONE AV TECHNOLOGIES

   |   www.milestone.com

P

 800.622.3737 / 574.267.8101  

F

 877.325.4832 / 574.267.7804   

E

 [email protected]

In British Columbia, Milestone AV Technologies ULC carries on business as MAVT Milestone AV Technologies ULC. 

©2018 Milestone AV Technologies. DL–0256 (Rev. 3) 04.18.  
Da-Lite is a registered trademarks of Milestone AV Technologies. All other brand names or marks are used for 
identification purposes and are trademarks of their respective owners. All patents are protected under existing 
designations. Other patents pending. 

Summary of Contents for Cosmopolitan Electrol

Page 1: ...INSTRUCTION BOOK FOR Cosmopolitan Electrol For Sizes Up To 9 x 12 ...

Page 2: ... electric shock when the appliance is used subsequently 11 The use of an accessory attachment not recommended by the manufacturer may cause a risk of fire electric shock or injury to persons 12 Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this ...

Page 3: ...th 8 Length B is the distance between wall mounting holes at back of end caps and is the fabric width 6 1 2 4 4 Motor End A B Installation 3 8 Diameter For Ceiling Installation Enclosure Cover 7 8 Diameter Opening For Electrical Fittings Picture Surface 1 29 32 5 32 7 8 Diameter Knock Out 4 23 32 5 7 8 6 3 32 1 3 16 ...

Page 4: ...uban adhésif avec un couteau ou un outil tranchant Retirez à la main 3 Install electrical hook up that applies to your unit Make sure to review your Electrical Installation Checklists and wiring diagrams included for either 120 volt switch 220 240 volt switch or low voltage control 4 Test installation by running screen up and down a few times Be prepared to stop screen Standard Duty Cycle 1 MIN ON...

Page 5: ...ver tighten fasteners or damage may occur 3 Attach screen securely to studding or other solid surface never to plaster only 4 MAKE SURE SCREEN IS MOUNTED LEVEL Ceiling Mounting 1 Heavy screw hooks may be installed into wood joists Other types of hooks or chain may be used for other ceilings or for stage installations 2 Insert hooks or chain through proper openings provided in sides of end caps Scr...

Page 6: ...Off Common White Black With Yellow Up Red Rocker Switch AC Common 120 V 60 Hz 2 5 Max Amp Operating Switch And Plate Furnished With Screen SPDT With Center Off In Multiple Control Installations This Switch Is Replaced By The Low Voltage Control Operated From Push Button Stations To Junction Box Mounted In Screen Case In Which Internal Wiring Terminates In White Black and Red Leads Down White Limit...

Page 7: ... 24 gauge wire can be used in place of the supplied RJ 14 cable to connect the wall switch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 3 conductor connection tha...

Page 8: ...ing code Blue AC Common Brown AC Hot 230V AC 50Hz Green Yellow Ground Jumper Wire Green Yellow Ground Motor NOTE A single switch cannot be used to operate more than one screen In multiple control installations this switch is replaced by the low voltage control operated from push button stations Contact the factory for further information To Junction Box Mounted In Screen Case In Which Internal Wir...

Page 9: ...lack Orange Purple Brown 220V Wiring Diagram with Operation Limit Adjustment Wall Switch 3 conductor 20 24 gauge wire can be used in place of the supplied RJ 14 cable to connect the wall switch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party co...

Page 10: ...all switch is for operation only and CANNOT be used to make limit switch adjustments Therefore it is advised to wire the limit adjustment switch or provide a 3 conductor connection that is accessible Power Input 220VAC 50Hz Green Yellow Ground Blue Hot Brown Common Power Wire Data Cable RJ 45 Jack Black Down White Common Red Up Red Black White Inputs Output Black Down White L Common Red Up Push Do...

Page 11: ...or s screen trigger output polarity does not matter The red and black wires from the VPI are interchangeable IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 3 conductor connection that is accessible 3 conductor 20 24 gauge wire can be used in place of the supplied RJ...

Page 12: ...re drop than what was ordered At least 1 1 2 wraps of fabric must remain on the roller This screen comes standard with 0 or 2 black at the top See the specification data sheet for details ATTENTION N effectuez pas de réglage pour obtenir un déroulement supérieur à celui commandé Au moins 1 à 1 2 tour de toile doit être maintenu sur le cylindre Cet écran est doté de série d une bande noire supérieu...

Page 13: ...the wall switch over and use the up button on front of switch Press and hold until the desired travel position is reached If you travel to far up you can press the down to move the screen downward If you press and let go of either up or down button the motor will do a small jog in that direction for finer adjustment of screen Once desired position is reached turn switch over press and hold up tact...

Page 14: ... closure across the common up and down wires will be a stop command Up Dry Contact Down Dry Contact Common Both Bus Bus 5V Bus Operation of Screens With A Built In Low Voltage Control or VPI Operation Limit Adjustment Wall Switch 1 Press DOWN button on screen switch and screen will deploy out of case in downward direction 2 Press STOP button on screen switch and screen will stop if in movement 3 P...

Page 15: ...connect Defective motor limit switch or capacitor Replace motor assembly NOTE Motor is a sealed assembly Capacitor burned out Replace motor assembly Incorrect stopping position in downward direction Lost roller wrap See instructions below Down limit switch out of adjustment See installation instructions Incorrect stopping position in upward direction Lost roller wrap See instructions below Up limi...

Page 16: ...SE AND MERCHANTABILITY Any implied warranties of fitness for use or merchantability that may be mandated by statute or rule of law are limited to the one 1 year warranty period This warranty gives you specific legal rights and you may also have other rights which vary from state to state TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW NO LIABILITY IS ASSUMED FOR EXPENSES OR DAMAGES RESULTING FRO...

Reviews: