background image

13

For Screens With A Built-In Low Voltage Control or VPI

1.  Locate the wall switch and remove the cover plate from  

the 3-button wall switch and remove the switch from the 
junction box.

2.  Locate the two tactile buttons on the back of the switch. They 

are square silver with black round buttons.

3.  To adjust the down limit switch, press and hold the down 

tactile button until the LED on back of switch turns solid red. 
This will put the motor in limit set mode.  Turn the wall switch 
over and use the down button on front of switch. Press and 
hold until the desired travel position is reached. If you travel 
to far down you can press the up to move the screen upward.  
If you press and let go of either up or down button the motor 
will do a small jog in that direction for finer adjustment of 
screen. Once desired position is reached turn switch over 
press and hold down tactile button until the LED on back of 
switch blinks red twice. The down limit is now set.

4.  To adjust the up limit switch, press and hold the up tactile 

button until the LED on back of switch turns solid green.  This 
will put the motor in limit set mode. Turn the wall switch over 
and use the up button on front of switch. Press and hold until 

the desired travel position is reached. If you travel to far up 
you can press the down to move the screen downward. If you 
press and let go of either up or down button the motor will 
do a small jog in that direction for finer adjustment of screen. 
Once desired position is reached turn switch over press and 
hold up tactile button until the LED on back of switch blinks 
green twice. The up limit is now set.

5.  To test limit switch setting, press and release the up or down 

button on the wall switch to operate the screen.

6.  Replace switch and cover plate on the wall.

 

NOTE: 

If the screen is in limit set mode and no buttons are 

pushed for 20 seconds, the LED on the back of the wall 
switch will turn off, the motor will return to run mode and no 
changes will be saved. If this occurs, return to step 3 for down 
limit adjustment or step 4 for up limit adjustment.

 

IMPORTANT NOTE:

 The wall switch is REQUIRED to make 

any limit switch adjustments, EVEN if a third party control 
system is used.  Therefore, it is advised to wire the switch or 
provide a 3-conductor connection that is accessible.

Screen Adjustment (continued)

UP

STOP

DOWN

BUS

C

O

M

5

V

Front of Wall 

Switch

UP

STOP

DOWN

BUS

C

O

M

5V

LED

Up Limit
Tactile Button

Down Limit
Tactile Button

Back of

Wall Switch

Summary of Contents for Cosmopolitan Electrol

Page 1: ...INSTRUCTION BOOK FOR Cosmopolitan Electrol For Sizes Up To 9 x 12 ...

Page 2: ... electric shock when the appliance is used subsequently 11 The use of an accessory attachment not recommended by the manufacturer may cause a risk of fire electric shock or injury to persons 12 Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this ...

Page 3: ...th 8 Length B is the distance between wall mounting holes at back of end caps and is the fabric width 6 1 2 4 4 Motor End A B Installation 3 8 Diameter For Ceiling Installation Enclosure Cover 7 8 Diameter Opening For Electrical Fittings Picture Surface 1 29 32 5 32 7 8 Diameter Knock Out 4 23 32 5 7 8 6 3 32 1 3 16 ...

Page 4: ...uban adhésif avec un couteau ou un outil tranchant Retirez à la main 3 Install electrical hook up that applies to your unit Make sure to review your Electrical Installation Checklists and wiring diagrams included for either 120 volt switch 220 240 volt switch or low voltage control 4 Test installation by running screen up and down a few times Be prepared to stop screen Standard Duty Cycle 1 MIN ON...

Page 5: ...ver tighten fasteners or damage may occur 3 Attach screen securely to studding or other solid surface never to plaster only 4 MAKE SURE SCREEN IS MOUNTED LEVEL Ceiling Mounting 1 Heavy screw hooks may be installed into wood joists Other types of hooks or chain may be used for other ceilings or for stage installations 2 Insert hooks or chain through proper openings provided in sides of end caps Scr...

Page 6: ...Off Common White Black With Yellow Up Red Rocker Switch AC Common 120 V 60 Hz 2 5 Max Amp Operating Switch And Plate Furnished With Screen SPDT With Center Off In Multiple Control Installations This Switch Is Replaced By The Low Voltage Control Operated From Push Button Stations To Junction Box Mounted In Screen Case In Which Internal Wiring Terminates In White Black and Red Leads Down White Limit...

Page 7: ... 24 gauge wire can be used in place of the supplied RJ 14 cable to connect the wall switch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 3 conductor connection tha...

Page 8: ...ing code Blue AC Common Brown AC Hot 230V AC 50Hz Green Yellow Ground Jumper Wire Green Yellow Ground Motor NOTE A single switch cannot be used to operate more than one screen In multiple control installations this switch is replaced by the low voltage control operated from push button stations Contact the factory for further information To Junction Box Mounted In Screen Case In Which Internal Wir...

Page 9: ...lack Orange Purple Brown 220V Wiring Diagram with Operation Limit Adjustment Wall Switch 3 conductor 20 24 gauge wire can be used in place of the supplied RJ 14 cable to connect the wall switch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party co...

Page 10: ...all switch is for operation only and CANNOT be used to make limit switch adjustments Therefore it is advised to wire the limit adjustment switch or provide a 3 conductor connection that is accessible Power Input 220VAC 50Hz Green Yellow Ground Blue Hot Brown Common Power Wire Data Cable RJ 45 Jack Black Down White Common Red Up Red Black White Inputs Output Black Down White L Common Red Up Push Do...

Page 11: ...or s screen trigger output polarity does not matter The red and black wires from the VPI are interchangeable IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 3 conductor connection that is accessible 3 conductor 20 24 gauge wire can be used in place of the supplied RJ...

Page 12: ...re drop than what was ordered At least 1 1 2 wraps of fabric must remain on the roller This screen comes standard with 0 or 2 black at the top See the specification data sheet for details ATTENTION N effectuez pas de réglage pour obtenir un déroulement supérieur à celui commandé Au moins 1 à 1 2 tour de toile doit être maintenu sur le cylindre Cet écran est doté de série d une bande noire supérieu...

Page 13: ...the wall switch over and use the up button on front of switch Press and hold until the desired travel position is reached If you travel to far up you can press the down to move the screen downward If you press and let go of either up or down button the motor will do a small jog in that direction for finer adjustment of screen Once desired position is reached turn switch over press and hold up tact...

Page 14: ... closure across the common up and down wires will be a stop command Up Dry Contact Down Dry Contact Common Both Bus Bus 5V Bus Operation of Screens With A Built In Low Voltage Control or VPI Operation Limit Adjustment Wall Switch 1 Press DOWN button on screen switch and screen will deploy out of case in downward direction 2 Press STOP button on screen switch and screen will stop if in movement 3 P...

Page 15: ...connect Defective motor limit switch or capacitor Replace motor assembly NOTE Motor is a sealed assembly Capacitor burned out Replace motor assembly Incorrect stopping position in downward direction Lost roller wrap See instructions below Down limit switch out of adjustment See installation instructions Incorrect stopping position in upward direction Lost roller wrap See instructions below Up limi...

Page 16: ...SE AND MERCHANTABILITY Any implied warranties of fitness for use or merchantability that may be mandated by statute or rule of law are limited to the one 1 year warranty period This warranty gives you specific legal rights and you may also have other rights which vary from state to state TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW NO LIABILITY IS ASSUMED FOR EXPENSES OR DAMAGES RESULTING FRO...