background image

 

 

d.s.f. GmbH BZ – V 24 TK Version 11/2021 

Page 

9 of 10 

 

Fig. 3 

 

1
2
3
4
8

C1
E1

F1
F2

G1
G2

H 1
H 2

K1

S 1
S 2

V32
V33

X1
X2

charging v
charging voltage -
protective conductor  PE
LED connection, tin-coated
LED anode connection
capacitor
heat sink
fast 2,5 A fuse
fast 3,15 A fuse
gel lead battery
gel lead battery
indicator light (yellow LED)
discharge voltage (red LED)
relay
switch (on/off)
push-button ON
spark gap
spark gap
charger connection
high-voltage connection

K 1

7 8

10

9

T 2

C 1

X2

V

 3

2

V

 3

3

E

 1

1

2

3

F 1

F 2 

X1

6

5

G 1

G 2

H 1

S 2

S 1

H 2

 

 

7.  

Maintenance 

 

Because of its heavy-duty design, the igniter does not require any maintenance. Should deposits 

settle on the spark plug due to the plant’s specific conditions, they can be removed with a cloth or 

a brush (

but do not use metal brushes, in order to avoid short circuits

). When doing so beware 

of the spark plug temperatures.  

 

8.  

Spares 

 

The high-energy spark plug and the spark gaps are wear parts and will not come under the war-

ranty conditions. The useful life of these parts depends on the number of ignitions and the ambient 

conditions.  

 

8.1.  Spare part list 

 

High-energy spark plug:  

Type HK 20/40  Part No. Z 100.3 

Spark gap: 

Type V 800 

Part No. Z 106 

Ignition lance with HV-cable:  

Type ZS 100 K  Part No. Z 122.1 (for example 1000 mm) 

 

 

Summary of Contents for BZ - V 24 TK

Page 1: ...Internationales Know How in der Flammen berwachung International Know How in Flame Detection Operating Instructions Portable Burner Igniter BZ V 24 TK...

Page 2: ...harger at the appliance inlet 4 2 Operating principle 5 3 Start up 5 4 Battery charger 6 4 1 Technical data of the battery charger 6 5 Faults break downs 7 6 Repairs 7 6 1 Replacing the high energy sp...

Page 3: ...ol switch underneath the appliance inlet for connecting the battery charger and the igniter will be activated by pressing the push button please observe the start up instructions A yellow LED installe...

Page 4: ...10 1 2 Casing configuration Fig 1 200 230 1 3 Connection of the battery charger at the appliance inlet Fig 2 1 2 3 4 5 6 protective conductor PE green yellow free charging voltage free free free blue...

Page 5: ...t be used If the red LED is on the discharge voltage is reached and the startup to be omitted and the batteries to be recharge immediately The igniter must only be started with the ignition lance insi...

Page 6: ...the cable socket of the spiral cable with the igniter Leave switch S1 at the igniter in the OFF position The green LED lamp indicating ready for operation and the red LED charging indicator at the ba...

Page 7: ...the wear parts Use only original spares Disconnect the battery charger during any repair work Put switch S1 in its O position before work ing on the appliance Remove fuse F 1 see Fig 3 immediately aft...

Page 8: ...approx 1 600 V for the ignition process will be generated in the appliance which may still be applied for to the HV capacitor and to the spark gap for a few seconds although the igniter has been swit...

Page 9: ...S 1 H 2 7 Maintenance Because of its heavy duty design the igniter does not require any maintenance Should deposits settle on the spark plug due to the plant s specific conditions they can be removed...

Page 10: ...possibly errors or defects may cause an exchange Requirement is that an error can be attributed to defects in components or manufacture The warranty is void if procedures are performed by the user or...

Reviews: