5.
Faults & break-downs
After connecting the ignition lance, turning on the control switch and pressing the push-button:
Fault
Possible cause
Remedy
No firing spark
Power cut
Charge batteries,
LED off
check fuse in the igniter
replace fuse, if necessary
LED lights only briefly
Defective spark plug
Replace spark plug
(see section “Repairs”)
HV-cable not properly
Connect cable at the
connected
electronics casing
Defective spark gap
Replace spark gap
(see section “Repairs”)
6.
Repairs
Warning!
Only suitably qualified staff is authorized to exchange the wear parts. Use only original spares.
Disconnect the battery charger during any repair work. Put switch S1 in its O-position before work-
ing on the appliance. Remove fuse F 1 (see Fig. 3) immediately after opening the cover lid. When
repairing the spark plug, disconnect the HV-cable from the igniter (by pulling out the HV-plug).
6.1. Replacing the high-energy-spark plug
•
Disconnect the HV-cable from the igniter
•
Unscrew the worn-out high-energy spark plug
(warning: high temperatures can be possible!)
•
Slide off the protective tube from the replacement plug; the thread has been treated with a
high-temperature paste (which prevents the spark plug from getting stuck in the socket)
•
Insert the new spark plug into the ignition lance and screw it in finger-tight
•
Re-assemble the plug-in reversed order