d.s.f. GmbH BZ – V 24 TK Version 11/2021
Page
6 of 10
Make sure during the ignition process that the maximum duration of one attempt does not exceed
2 min (danger of overheating the power electronics). Igniting several burners successively should
not cause problems, since the change-over time in between is sufficient to let the individual burners
cool down thus avoiding excess temperatures. After the ignition process has been completed, dis-
connect the operating voltage by turning off switch S1 and, for better handling, remove the lance
from the igniter.
Make sure during shipments of the high-energy igniter that switch S1 (connection with the
mains) is turned off.
4.
Battery charger
The automatic desk-top battery chargers type ALCT 6-24/2 and type ALCT 6-24/2G are
intended for charging the lead-acid batteries installed in the igniter. No warranty will be
granted, when other battery chargers are used.
Connect the power plug with the 230 V AC / 50 Hz mains socket and the cable socket of
the spiral cable with the igniter. Leave switch S1 at the igniter in the OFF position. The
green LED lamp indicating ready for operation and the red LED charging indicator at the
battery charger are lighting up. If the green LED lamp goes out, the system is short-cir-
cuited or the battery is defective and the power supply must be cut off. If the red LED lamp
goes out, the charging current is less than 200 mA and the batteries are fully charged.
Unplug the power cable from the socket and disconnect the igniter.
Technical data of the battery charger:
Input voltage:
230 V AC / 50 Hz ±10 %
Output voltage:
24 V DC, 1.0 A
Charging characteristic:
IU
Charging end:
at 27.6 V DC set as default value
Temperature range:
-10° C … +30° C
Degree of protection:
IP 20 (optional IP 65 for the casing)
Protection class:
II
Casing:
ABS (optional: aluminum die-cast with carrier handle)
Dimensions:
(w x h x d) 140 x 100 x 80 mm (200 x 140 x 91 mm)
Weight:
1.25 kg (in the casing: 2.3 kg)
Protective device:
electronic protection against short-circuit, false polarity and
overloading, temperature-fused
Displays:
1 green & red LED each
Standard:
corresponds to EN 60-335-2-29
Approvals:
CE, S, D, FI