d.s.f. GmbH BZ – V 24 TK Version 11/2021 

Page 

6 of 10 

Make sure during the ignition process that the maximum duration of one attempt does not exceed 

2 min (danger of overheating the power electronics). Igniting several burners successively should 

not cause problems, since the change-over time in between is sufficient to let the individual burners 

cool down thus avoiding excess temperatures. After the ignition process has been completed, dis-

connect the operating voltage by turning off switch S1 and, for better handling, remove the lance 

from the igniter.  

Make sure during shipments of the high-energy igniter that switch S1 (connection with the 

mains) is turned off. 

 

4.  

Battery charger 

 

The automatic desk-top battery chargers type ALCT 6-24/2 and type ALCT 6-24/2G are 

intended for  charging the  lead-acid batteries  installed  in  the  igniter.  No  warranty  will  be 

granted, when other battery chargers are used. 

Connect the power plug with the 230 V AC / 50 Hz mains socket and the cable socket of 

the spiral cable with the igniter. Leave switch S1 at the igniter in the OFF position. The 

green LED lamp indicating ready for operation and the red LED charging indicator at the 

battery charger are lighting up. If the green LED lamp goes out, the system is short-cir-

cuited or the battery is defective and the power supply must be cut off. If the red LED lamp 

goes  out,  the  charging  current  is  less  than  200 mA and  the batteries  are fully  charged. 

Unplug the power cable from the socket and disconnect the igniter.  

 

Technical data of the battery charger: 

 

Input voltage: 

230 V AC / 50 Hz ±10 % 

Output voltage: 

24 V DC, 1.0 A 

Charging characteristic: 

IU 

Charging end: 

at 27.6 V DC set as default value 

Temperature range: 

-10° C … +30° C 

Degree of protection: 

IP 20 (optional IP 65 for the casing) 

Protection class: 

 

 

II 

 

Casing: 

 ABS (optional: aluminum die-cast with carrier handle) 

 
Dimensions: 

(w x h x d) 140 x 100 x 80 mm (200 x 140 x 91 mm) 

Weight: 

1.25 kg (in the casing: 2.3 kg) 

Protective device: 

electronic protection against short-circuit, false polarity and  

 

overloading, temperature-fused 

Displays: 

1 green & red LED each 

Standard: 

corresponds to EN 60-335-2-29 

Approvals: 

CE, S, D, FI 

 

Summary of Contents for BZ - V 24 TK

Page 1: ...Internationales Know How in der Flammen berwachung International Know How in Flame Detection Operating Instructions Portable Burner Igniter BZ V 24 TK...

Page 2: ...harger at the appliance inlet 4 2 Operating principle 5 3 Start up 5 4 Battery charger 6 4 1 Technical data of the battery charger 6 5 Faults break downs 7 6 Repairs 7 6 1 Replacing the high energy sp...

Page 3: ...ol switch underneath the appliance inlet for connecting the battery charger and the igniter will be activated by pressing the push button please observe the start up instructions A yellow LED installe...

Page 4: ...10 1 2 Casing configuration Fig 1 200 230 1 3 Connection of the battery charger at the appliance inlet Fig 2 1 2 3 4 5 6 protective conductor PE green yellow free charging voltage free free free blue...

Page 5: ...t be used If the red LED is on the discharge voltage is reached and the startup to be omitted and the batteries to be recharge immediately The igniter must only be started with the ignition lance insi...

Page 6: ...the cable socket of the spiral cable with the igniter Leave switch S1 at the igniter in the OFF position The green LED lamp indicating ready for operation and the red LED charging indicator at the ba...

Page 7: ...the wear parts Use only original spares Disconnect the battery charger during any repair work Put switch S1 in its O position before work ing on the appliance Remove fuse F 1 see Fig 3 immediately aft...

Page 8: ...approx 1 600 V for the ignition process will be generated in the appliance which may still be applied for to the HV capacitor and to the spark gap for a few seconds although the igniter has been swit...

Page 9: ...S 1 H 2 7 Maintenance Because of its heavy duty design the igniter does not require any maintenance Should deposits settle on the spark plug due to the plant s specific conditions they can be removed...

Page 10: ...possibly errors or defects may cause an exchange Requirement is that an error can be attributed to defects in components or manufacture The warranty is void if procedures are performed by the user or...

Reviews: