background image

xStack® DGS-3420 Series Layer 2+ Managed Stackable Gigabit Switch Hardware Installation Reference Guide 

28 

 

Figure 3–2 Connect the Switch to a port on a switch with a straight or crossover cable 

 

Connect to a Network Backbone or Server 

The combo SFP ports and the 1000BASE-T ports are ideal for uplinking to a network backbone, server or server farm. 
The copper ports operate at a speed of 10/100/1000Mbps in half or full duplex mode. The fiber-optic ports can operate at 
both 100Mbps and 1000Mbps in full duplex mode. 

 

You can connect to the Gigabit Ethernet ports using a fiber-optic cable or a Category 5E copper cable, depending on the 
type of port. The Link LED turns green when a connection is made.  

 

 

Figure 3–3 Connect a DGS-3420 Series Switch to a server 

 

Summary of Contents for xStack

Page 1: ......

Page 2: ...radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Warnung Dies ist ein Produk...

Page 3: ...ing Brackets to a Switch for Rack Mounting 19 Mounting the Switch in a Standard 19 Rack 20 Power On AC Power 20 Power Failure AC Power 20 Alarm Connector 20 Installing SFP and SFP Ports 22 Connecting to a Redundant Power Supply 23 External Redundant Power System 24 DPS 900 24 DPS 800 25 Chapter 3 Connecting the Switch 27 Switch to End Node 27 Switch to Switch 27 Connect to a Network Backbone or Se...

Page 4: ...Pages 37 Appendix Section 39 Appendix A Technical Specifications 39 General 39 Physical and Environmental 39 Performance 40 LED Indicators 41 Port Functions 43 Appendix B Cables and Connectors 46 Ethernet Cable 46 Console Cable 47 Redundant Power Supply RPS Cable 48 Appendix C Module Specs and Cable Lengths 50 Warranties Technical Support 51 ...

Page 5: ...nu and choose Cancel Used for emphasis May also indicate system messages or prompts appearing on screen For example You have mail Bold font is also used to represent filenames program names and commands For example use the copy command Boldface Typewriter Font Indicates commands and responses to prompts that must be typed exactly as printed in the manual Initial capital letter Indicates a window n...

Page 6: ...nents Use the product only with approved equipment Allow the product to cool before removing covers or touching internal components Operate the product only from the type of external power source indicated on the electrical ratings label If unsure of the type of power source required consult your service provider or local power company To help avoid damaging the system be sure the voltage selectio...

Page 7: ... resulting in bodily injury under certain circumstances Therefore always install the stabilizers before installing components in the rack After installing system components in a rack never pull more than one component out of the rack on its slide assemblies at one time The weight of more than one extended component could cause the rack to tip over and may result in serious injury Before working on...

Page 8: ...lectricity from your body before touching any of the electronic components such as the microprocessor This can be done by periodically touching an unpainted metal surface on the chassis The following steps can also be taken prevent damage from electrostatic discharge ESD 1 When unpacking a static sensitive component from its shipping carton do not remove the component from the antistatic packing m...

Page 9: ...enty Copper PoE ports 10 100 1000Mbps Four Combo Copper SFP ports 10 100 1000Mbps and 100 1000Mbps Four SFP ports 10GE Layer 2 Stackable Managed Switch DGS 3420 52T Fourty eight Copper ports 10 100 1000Mbps Four SFP ports 10GE Layer 2 Stackable Managed Switch DGS 3420 52P Fourty eight Copper PoE ports 10 100 1000Mbps Four SFP ports 10GE Layer 2 Stackable Managed Switch This cost effective Gigabit ...

Page 10: ...ual LAN 802 1Q with up to 4K static VLAN groups and 255 dynamic VLAN groups Supports Port based and MAC based VLAN Supports VLAN trunking and Asymmetric VLAN Supports ISM Private Subnet based Voice and Double VLAN Q in Q Supports VLAN Translation Supports IP Interfaces with up to 256 IP interfaces Supports Loopback Interface of up to 8 IPv4 interfaces Supports Gratuitous ARP and ARP Proxy Supports...

Page 11: ...upport Multiple Images and Multiple Configurations Suports Flash File System using either a FAT16 or FAT32 SD Card Supports Password Encryption and Password Recovery Supports Simple Network Time Protocol SNTP with the Precision Time Protocol PTP Supports Network Load Balancing NLB with both IPv4 and IPv6 support Supports Simple Mail Transfer Protocol SMTP Support Ethernet Link Object Access Method...

Page 12: ...r ports 10 100 1000Mbps Four SFP ports 10GE DGS 3420 52P Fourty eight Copper PoE ports 10 100 1000Mbps Four SFP ports 10GE All the switches are equipt with one RJ 45 Console port a special console cable with a DB9 interface is provided to connect the Switch to a PC All the switches are equipt with one Redundant Power Supply RPS outlet for optional external RPS All the switches are also equipt with...

Page 13: ...wer Console an Alarm Port and stacking ID LED s A separate table below describes LED indicators in more detail Figure 1 1 Front panel view of a DGS 3420 28SCSwitch Figure 1 2 Front panel view of a DGS 3420 28TC Switch Figure 1 3 Front panel view of a DGS 3420 26SC Switch Figure 1 4 Front panel view of a DGS 3420 28PC Switch Figure 1 5 Front panel view of a DGS 3420 52T Switch Figure 1 6 Front pane...

Page 14: ...for all ports including the Gigabit Ethernet ports The DGS 3420 28PC and DGS 3420 52P switches are equipt with an additional PoE light to indication whether the ports are running in Power over Ethernet mode Figure 1 7 LED indicators for the DGS 3420 28SC Figure 1 8 LED indicators for the DGS 3420 28TC Figure 1 9 LED indicators for the DGS 3420 26SC Figure 1 10 LED indicators for the DGS 3420 28PC ...

Page 15: ...tion in the stacking box ID The box ID is assigned either by the user static mode or by the system automatic mode When 1 to 12 is displayed this indicates the stacking position of the switch An H indicates the device was assigned as the stacking Master h means the device was selected to be the Backup Master A G is displayed when the Safeguard Engine feature enters the exhausted mode Link Act LEDs ...

Page 16: ...GS 3420 52T Switch Figure 1 18 Rear panel view of a DGS 3420 52P Switch The AC power connector is a standard three pronged connector that supports the power cord Plug in the female connector of the provided power cord into this socket and the male side of the cord into a power outlet The Switch automatically adjusts the power setting to any supply voltage in the range from 100 240 VAC at 50 60 Hz ...

Page 17: ...pace at the rear and sides of the Switch for proper ventilation Be reminded that without proper heat dissipation and air circulation system components might overheat which could lead to system failure or even severely damage components Figure 1 19 Side panels of the DGS 3420 28SC Switch Figure 1 20 Side panels of the DGS 3420 28TC Switch Figure 1 21 Side panels of the DGS 3420 26SC Switch Figure 1...

Page 18: ...tack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch Hardware Installation Reference Guide 17 Figure 1 23 Side panels of the DGS 3420 52T Switch Figure 1 24 Side panels of the DGS 3420 52P Switch ...

Page 19: ... follow these guidelines for setting up the Switch Install the Switch on a sturdy level surface that can support at least 6 6 lb 3kg This is without PoE functionality of weight Do not place heavy objects on the Switch The power outlet should be within 1 82 meters 6 feet of the Switch Visually inspect the power cord and see that it is fully secured to the AC power port Make sure that there is prope...

Page 20: ... 1 Attach rubber feet to the switch Attaching Brackets to a Switch for Rack Mounting The Switch is mounted to a standard 19 rack using mounting brackets Use the following diagrams as a guide Figure 2 2 Attach mounting brackets to the switch Fasten the mounting brackets to the Switch using the screws provided With the brackets attached securely the Switch can be mounted in a standard rack as shown ...

Page 21: ...recaution unplug the Switch After the power returns plug the switch back in to the power socket CAUTION Installing systems in a rack without the front and side stabilizers installed could cause the rack to tip over potentially resulting in bodily injury under certain circumstances Therefore always install the stabilizers before installing components in the rack After installing components in a rac...

Page 22: ...Port Contact Description 1 Output Normal Closed Pin 42VAC or 60VDC 2 Output Common Pin 42VAC or 60VDC 3 Output Normal Open Pin 42VAC or 60VDC 4 Input 2 5 Input 2 6 Input 1 7 Input 1 Connect the alarm input pins to alarm output terminals on other pieces of equipment Connect the alarm output pins to alarm input terminals on other pieces of equipment ...

Page 23: ...ort full duplex transmissions auto negotiation and can be uplinked with various other switches across a gigabit network The SFP ports support data rates of up to 1Gbit s and the SFP ports support data rates of up to 10Gbit s See the figure below for installing the SFP ports in the Switch Figure 2 5 Inserting fiber optic transceivers into a DGS 3420 Series Switch For a full list of supported transc...

Page 24: ...r cable into the port on the switch and the other end into the redundant power supply 2 Using a standard AC power cable connect the redundant power supply to the main AC power source A green LED on the front of the DPS 500 will glow to indicate a successful connection 3 Re connect the switch to the AC power source The LED indicator will show that a redundant power supply is now in operation 4 Do n...

Page 25: ...stalled into a DPS 900 or DPS 800 rack mount unit DPS 900 The DPS 900 is a standard size rack mount 5 standard units in height designed to hold up to eight DPS 500 redundant power supplies However it cannot hold eight DGS 700 modules Figure 2 7 Inserting the DPS 500 into the DPS 900 The RPS can be mounted in a standard 19 rack Use the following diagram to guide you CAUTION DO NOT connect the RPS t...

Page 26: ...bodily injury under certain circumstances Therefore always install the stabilizers before installing components in the rack After installing components in a rack do not pull more than one component out of the rack on its slide assembly at a time The weight of more than one extended component could cause the rack to tip over and may result in injury DPS 800 The DPS 800 is a standard size rack mount...

Page 27: ...kable Gigabit Switch Hardware Installation Reference Guide 26 Figure 2 9 Install the DPS 500 in the DPS 800 The RPS can be mounted in a standard 19 rack Use the following diagram to guide you Figure 2 10 Install the DPS 800 in an Equipment Rack ...

Page 28: ...active A blinking LED indicates packet activity on that port Figure 3 1 Connect a DGS 3420 Series Switch to an end node NOTE All high performance N Way Ethernet ports can support both MDI II and MDI X connections Switch to Switch There is a great deal of flexibility on how connections are made using the appropriate cabling Connect a 10BASE T switch port to the Switch via a twisted pair Category 3 ...

Page 29: ...ts are ideal for uplinking to a network backbone server or server farm The copper ports operate at a speed of 10 100 1000Mbps in half or full duplex mode The fiber optic ports can operate at both 100Mbps and 1000Mbps in full duplex mode You can connect to the Gigabit Ethernet ports using a fiber optic cable or a Category 5E copper cable depending on the type of port The Link LED turns green when a...

Page 30: ...hrough the Serial Port or remote Telnet The user can also connect a computer or terminal to the serial console port to access the DGS 3420 range The command line interface provides complete access to all DGS 3420 Series of switches management features Connecting the Console Port The console port on the front panel of the Switch is used to connect a computer that monitors and configures the switch ...

Page 31: ...the logout command or close the emulator program If you experience problems while making a connection make sure the emulation is set to VT 100 The emulation settings can be configured by 1 Click File Menu in HyperTerminal 2 Click Properties from the drop down menu 3 Click the Settings Tab This is where you will find the Emulation options If you still do not see anything try rebooting the Switch by...

Page 32: ...ted for the Switch Connecting to the Management Port The front panel of the Switch features an out of band RJ 45 Management port which can easily connect to a notebook Connect to the out of bound management console using a web browser or Telnet command prompt interface This is the default login interface and is the tool you can use when connecting to the Switch for the first time To use the Manage...

Page 33: ...t appears NOTE Passwords are case sensitive User names and passwords can be up to 15 characters in length The sample below illustrates a successful creation of a new administrator level account with the user name newmanager DGS 3420 28SC admin create account admin newmanager Command create account admin newmanager Enter a case sensitive new password Enter the new password again for confirmation Su...

Page 34: ...ation window in the Configuration folder The IP address for the Switch must be set before it can be managed with the Web based manager The Switch IP address can be automatically set using BOOTP or DHCP protocols in which case the actual address assigned to the Switch must be known The IP address may be set using the Command Line Interface CLI over the console serial port as follows Starting at the...

Page 35: ...tor may specify which SNMP version to use to monitor and control the Switch The three SNMP versions vary in the level of security provided between the management station and the network device In SNMP v1 and v2 user authentication is accomplished using community strings which function like passwords The remote user SNMP application and the Switch SNMP must use the same community string SNMP packet...

Page 36: ...s for Authentication Failure Topology Change and Broadcast Multicast Storm Management Information Base MIB The Switch in the Management Information Base MIB stores management and counter information The Switch uses the standard MIB II Management Information Base module Consequently values for MIB objects can be retrieved from any SNMP based network management software In addition to the standard M...

Page 37: ... directly with the Switch using the HTTP protocol Logging onto the Web Manager To begin managing the Switch simply run the browser installed on your computer and point it to the IP address you have defined for the device The URL in the address bar should read something like http 123 123 123 123 where the numbers 123 represent the IP address of the Switch NOTE The factory default IP address for a n...

Page 38: ... subfolders contained within them to display windows Area 2 Presents a graphical near real time image of the front panel of the Switch This area displays the Switch s ports and expansion modules and shows port activity depending on the specified mode Some management functions including port monitoring are accessible here Click the D Link logo to go to the D Link Website Area 3 Presents Switch stat...

Page 39: ...unctionality of the Switch QoS In this section the user will be able to configure features regarding the Quality of Service functionality of the Switch ACL In this section the user will be able to configure features regarding the Access Control List functionality of the Switch Security In this section the user will be able to configure features regarding the Switch s security Network Application I...

Page 40: ...igabit Ethernet Half duplex Full duplex 10 Mbps 20Mbps 100Mbps 200Mbps 2Gbps 20Gbps Stacking Topology Duplex Ring Duplex Chain Network Cables Cat 5 Enhanced for 1000BASE T UTP Cat 5 Cat 5 Enhanced for 100BASE TX UTP Cat 3 4 5 for 10BASE T EIA TIA 568 100 ohm screened twisted pair STP 100m Physical and Environmental Feature Detailed Description Internal Power Supply AC Input 100 240VAC 50 60Hz Opti...

Page 41: ...imensions DGS 3420 28SC 441mm W x 310mm D x 44mm H DGS 3420 28TC 441mm W x 310mm D x 44mm H DGS 3420 26SC 441mm W x 310mm D x 44mm H DGS 3420 28PC 441mm W x 380mm D x 44mm H DGS 3420 52T 441mm W x 380mm D x 44mm H DGS 3420 52P 441mm W x 380mm D x 44mm H Weight DGS 3420 28SC 4 06kg DGS 3420 28TC 4 12kg DGS 3420 26SC 4 04kg DGS 3420 28PC 5 75kg DGS 3420 52T 5 07kg DGS 3420 52P 6 24kg EMI CE Class A ...

Page 42: ...s LED Indicators Location LED Indicative Color Status Description Per Device Power Green Solid Light Power on Light off Power off Console Green Solid Light Console on Light off Console off RPS Green Blinking When switch detects that RPS is connected Solid Light RPS in using Light off RPS off SD Green Solid Light Plugged in Blinking Busy Reading and Writing Light off No link Red Solid Light Read Wr...

Page 43: ...00Mbps Ethernet device at any of the ports Blinking When there is reception or transmission of data occurring at 10 100Mbps Off Light off No link PoE Mode Green Solid Light Power feeding Orange Solid Light Error Condition Off Light Off No Power feeding LED per SFP Port Link Act Green Solid Light When there is a secure connection or link to 1000Mbps Ethernet device at any of the ports Blinking When...

Page 44: ...3x Flow Control support for Full Duplex mode IEEE 802 3ab compliance IEEE 802 3af compliance DGS 3420 28PC DGS 3420 52P only IEEE 802 3at compliance DGS 3420 28PC DGS 3420 52P only SFP ports compliant to following standards IEEE 802 3z compliance SFP Transceivers Supported DEM 310GT 1000BASE LX Single mode 10km DEM 311GT 1000BASE SX Mutli mode 550m DEM 312GT2 1000BASE SX Multi mode 2km DEM 314GT 1...

Page 45: ... other ports active Power Classification Table Class Usage Max power used by PD 0 Default 12 95W 1 Optional 3 84W 2 Optional 6 49W 3 Optional 12 95W 4 Reserved 12 95W For 802 3at capable devices provide power allocation of 0 1 watt granularity using LLDP method Class Usage Minimum power levels of output of PSE 0 Default 15 4W 1 Optional 4 0W 2 Optional 7 0W 3 Optional 15 4W 4 Reserved 31W Class Us...

Page 46: ...ceiver 220m OM1 OM2 MMF 300m OM3 MMF DEM 435XT 10GBASE LRM SFP Transceiver w o DDM 220m OM1 OM2 MMF 300m OM3 MMF DEM 436XT BXU 10GBASE LR BiDi SFP Transceiver w o DDM 20km TX 1270nm RX 1330nm DEM 436XT BXD 10GBASE LR BiDi SFP Transceiver w o DDM 20km TX 1330nm RX 1270nm DEM 310GT 1000BASE LX Single mode 10km DEM 311GT 1000BASE SX Mutli mode 550m DEM 312GT2 1000BASE SX Multi mode 2km DEM 314GT 1000...

Page 47: ...lease review these products for matching cable pin assignment The following diagrams and tables show the standard RJ 45 connector and their pin assignments Figure 5 3 Standard RJ 45 port and connector RJ 45 Pin Assignments Pin MDI X Port MDI II Port 1 RD receive TD transmit 2 RD receive TD transmit 3 TD transmit RD receive 4 1000BASE T 1000BASE T 5 1000BASE T 1000BASE T 6 TD transmit RD receive 7 ...

Page 48: ...ole cable is necessary The following diagrams and tables show the standard Console to DJ 45 receptacle connector and their pin assignments Figure 5 4 Console to RJ 45 Cable Console RJ 45 Pin Assignments Pin Console DB9 RS232 RJ 45 1 Not Used Not Used 2 RXD Not Used 3 TXD TXD 4 Not Used GND 5 GND shared GND 6 Not Used RXD 7 Not Used Not Used 8 Not Used Not Used ...

Page 49: ...or and their pin assignments NOTE The DGS 3420 28PC and the DGS 3420 52P use the RPS 700 and not the RPS 500 Both devices have their own cables included in the package Figure 5 5 Redundant Power Supply RPS Cable DPS 500 DPS 700 RPS Cable Pin Assignments Pin Device DPS 500 1 GND GND 2 NC NC 3 12V 12V 4 12V 12V 5 12V 12V 6 12V 12V 7 GND GND 8 GND GND 9 NC Power Good 10 NC Power Present 11 Power Good...

Page 50: ...rence Guide 49 5 12V 12V 6 12V 12V 7 NC GND NC GND 8 12vsen 12Ven 9 LS 54v LS 54V 10 54V 54V 11 54Vrtn 54Vrtn 12 GND GND 13 GND NC GND NC 14 RPS Present RPS Present 15 Status_1 RPS PG 16 Status_2 GND 17 RPS PG Status_1 18 GND Status_2 19 12VRTNsen 12VRTNsen 20 LS 12V LS 12V 21 54Vsen 54Vsen ...

Page 51: ...000BASE LX Single mode 10km DEM 311GT 1000BASE SX Multi mode 550m DEM 312GT2 1000BASE SX Multi mode 2km DEM 314GT 1000BASE LHX Single mode 50km DEM 315GT 1000BASE ZX Single mode 80km DEM 210 100BASE FX Single mode 15km DEM 211 100BASE FX Multi mode 2km DEM 220T 100BASE BX Single mode Up to 20km DEM 220R 100BASE BX Single mode Up to 20km DEM 330T TX 1550 RX 1310nm Single mode Up to 10km DEM 330R TX...

Page 52: ...ation pertaining to the product and in that case the product is being sold As Is without any warranty whatsoever including without limitation the Warranty as described herein notwithstanding anything stated herein to the contrary Submitting A Claim The customer shall return the product to the original purchase point based on its return policy In case the return policy period has expired and the pr...

Page 53: ...ms Inc Other trademarks or registered trademarks are the property of their respective owners Copyright Statement No part of this publication or documentation accompanying this product may be reproduced in any form or by any means or used to make any derivative such as translation transformation or adaptation without permission from D Link Corporation D Link Systems Inc as stipulated by the United ...

Page 54: ...Registration Register your D Link product online at http support dlink com register Product registration is entirely voluntary and failure to complete or return this form will not diminish your warranty rights ...

Page 55: ...e warranty period on this product U S and Canadian customers can contact D Link technical support through our website or by phone Tech Support for customers within the United States D Link Technical Support over the Telephone USA 877 DLINK 55 877 354 6555 D Link Technical Support over the Internet http support dlink com Tech Support for customers within Canada D Link Technical Support over the Tel...

Page 56: ...00pm Sat 10 00am 02 00pm 0 05ppm peak 0 045ppm off peak Times Internet http dlink com Technische Unterstützung Deutschland Web http dlink com Telefon 49 0 1805 2787 0 14 pro Minute Zeiten Mo Fr 08 30 17 30 Uhr Österreich Web http dlink com Telefon 43 0 820 480084 0 116 pro Minute Zeiten Mo Fr 08 30 17 30 Uhr Schweiz Web http dlink com Telefon 41 0 848 331100 0 08 CHF pro Minute Zeiten Mo Fr 08 30 ...

Page 57: ...15per minuut Tech Support for customers within Belgium http dlink com 028801640 0 175per minuut spitsuren 0 0875per minuut daluren Technische ondereuning voor klanten in Luxemburg http dlink com 32 70 66 06 40 Asistencia Técnica Asistencia Técnica Telefónica de D Link 34 902 30 45 45 0 067 min De Lunes a Viernes de 9 00 a 19 00 http dlink com Supporto tecnico Supporto Tecnico dal lunedì al venerdì...

Page 58: ... 17 00 Volání je zpoplatněno dle příslušných tarifů Vašeho operátora Technikai Támogatás Tel 06 1 461 3001 Fax 06 1 461 3004 Land Line 14 99 HUG min Mobile 49 99 HUF min email support dlink hu URL http dlink com Teknisk Support D Link Teknisk Support over Internett http dlink com D Link Teknisk telefonsupport 815 69 755 Hverdager 08 00 17 00 Teknisk Support D Link teknisk support over telefonen Tl...

Page 59: ...pport Center http dlink com Καλύμνου 12 112 51 Αθήνα Τηλ 213 0020353 Δευτέρα Παρασκευή 09 00 19 00 Fax 210 8653172 Assistência Técnica Assistência Técnica da D Link na Internet http dlink com e mail soporte dlink es Teknisk Support D Link Teknisk Support via Internet http dlink com D Link Teknisk Support via telefon 0770 33 00 35 Vardagar 08 00 17 00 ...

Page 60: ...ink com Tehnična podpora Zahvaljujemo se vam ker ste izbrali D Link proizvod Za vse nadaljnje informacije podporo ter navodila za uporabo prosimo obiščite D Link ovo spletno stran www dlink eu http dlink com Suport tehnic Vă mulţumim pentru alegerea produselor D Link Pentru mai multe informaţii suport şi manuale ale produselor vă rugăm să vizitaţi site ul D Link www dlink eu http dlink com ...

Page 61: ...day 9 30AM to 6 30PM Thursdays 9 30AM to 2 00 PM E mail Support sa dlink me com D Link Middle East Dubai U A E Plot No S31102 Jebel Ali Free Zone South P O Box 18224 Dubai U A E Tel 971 4 8809022 Fax 971 4 8809066 8809069 Technical Support 971 4 8809033 General Inquiries info me dlink me com Tech Support support me dlink me com Egypt 1 Makram Ebeid Street City Lights Building Nasrcity Cairo Egypt ...

Page 62: ...one 212 663 72 73 24 Email support na dlink me com Lebanon RMA center Dbayeh Lebanon PO Box 901589 Tel 961 4 54 49 71 Ext 14 Fax 961 4 54 49 71 Ext 12 Email taoun dlink me com Bahrain Technical Support 973 1 3332904 Kuwait Technical Support 965 22453939 965 22453949 Türkiye Merkez İrtibat Ofisi Ayazağa Maslak yolu Erdebil Cevahir İş Merkezi No 5 A Ayazağa Maslak İstanbul Tel 90 212 2895659 Ücretsi...

Page 63: ...0 г Киев ул Межигорская 87 А офис 18 Тел 38 044 545 64 40 E mail kiev dlink ru Беларусь 220114 г Минск проспект Независимости 169 БЦ XXI Век Тел 375 17 218 13 65 E mail minsk dlink ru Казахстан 050008 г Алматы ул Курмангазы 143 уг Муканова Tел факс 7 727 378 55 90 E mail almaty dlink ru Армения 0038 г Ереван ул Абеляна 6 1 4 этаж Тел Факс 374 10 398 667 E mail erevan dlink ru Грузия Тел Факс 995 5...

Page 64: ...s siguientes teléfonos de D Link PAIS NUMERO Argentina 0800 12235465 Chile 800 260200 Colombia 01800 510070 Costa Rica 0800 0521478 Ecuador 1800 035465 El Salvador 800 6335 Guatemala 1800 8350255 México 01800 0626270 Panamá 011 008000525465 Perú 0800 00968 Venezuela 0800 1005767 Soporte Técnico de D Link a través de Internet Horario de atención Soporte Técnico en www dlinkla com e mail soporte dli...

Page 65: ...Suporte Técnico Caso tenha dúvidas na instalação do produto entre em contato com o Suporte Técnico D Link Acesse o site www dlink com br suporte ...

Page 66: ...區技術支援工程師聯絡 D Link 免付費技術諮詢專線 0800 002 615 手機付費電話 02 6600 0123 8715 服務時間 週一至週五 早上9 00到晚上9 00 不含周六 日及國定假日 網 站 http www dlink com tw 電子郵件 dssqa_service dlink com tw 如果您是台灣地區以外的用戶 請參考D Link網站全球各地 分公司的聯絡資訊以取得相關支援服務 產品保固期限 台灣區維修據點查詢 請參考以下網頁說明 http www dlink com tw 產品維修 使用者可直接送至全省聯強直營維修站或請洽您的原購買經銷商 ...

Page 67: ...okumentasi pengguna dapat diperoleh pada situs web D Link Dukungan Teknis untuk pelanggan Dukungan Teknis D Link melalui telepon Tel 62 21 5731610 Dukungan Teknis D Link melalui Internet Email support dlink co id Website http support dlink co id ...

Page 68: ...Technical Support この度は弊社製品をお買い上げいただき 誠にありがとうご ざいます 下記弊社 Web サイトからユーザ登録及び新製品登録を 行っていただき ダウンロードサービスにて サポート情報 ファームウェア ユーザマニュアルを ダウンロードすることができます ディーリンクジャパン Web サイト URL http www dlink jp com ...

Page 69: ...技术支持 办公地址 北京市东城区北三环东路 36 号 环球贸易中心 B 座 26F 02 05 室 邮编 100013 技术支持中心电话 400 629 6688 技术支持中心传真 028 87300889 各地维修中心地址请登陆官方网站查询 网址 http www dlink com cn 400电话工作时间 工作日9 00 19 00 节假日9 00 18 00 ...

Page 70: ... site 1 employee 2 9 10 49 50 99 100 499 500 999 1000 or more 3 What network protocol s does your organization use XNS IPX TCP IP DECnet Others_____________________________ 4 What network operating system s does your organization use D Link LANsmart Novell NetWare NetWare Lite SCO Unix Xenix PC NFS 3Com 3 Open Cisco Network Banyan Vines DECnet Pathwork Windows NT Windows 98 Windows 2000 ME Windows...

Page 71: ......

Reviews: