![D-Link DXS-3227 - xStack Switch - Stackable Cli Manual Download Page 17](http://html.mh-extra.com/html/d-link/dxs-3227-xstack-switch-stackable/dxs-3227-xstack-switch-stackable_cli-manual_78172017.webp)
D-Link CLI Reference Guide
Page 16
Note
The following steps are for use on the console line only.
To start using the CLI, perform the following steps:
1.
Connect the DB9 null-modem or cross over cable to the RS-232 serial port of the device to the RS-232 serial
port of the terminal or computer running the terminal emulation application.
a) Set the data format to 8 data bits, 1 stop bit, and no parity.
b) Set Flow Control to
none
.
c) Under
Properties
, select
VT100 for Emulation
mode.
d) Select
Terminal keys
for
Function, Arrow, and Ctrl keys
. Ensure that the setting is for
Terminal keys
(not
Windows keys
).
Note
When using HyperTerminal with Microsoft® Windows 2000,ensure that Windows® 2000 Service Pack 2
or later is installed.With Windows 2000 Service Pack 2, the arrow keys function properly in
HyperTerminal’s VT100 emulation. Go to www.microsoft.com for information on Windows 2000 service
packs.
2.
Enter the following commands to begin the configuration procedure:
Console>
enable
Console#
configure
Console(config)#
3.
Configure the device and enter the necessary commands to complete the required tasks.
4.
When finished, exit the session with the
exit
command.
When a different user is required to log onto the system, use the
login
Privileged EXEC mode command. This
effectively logs off the current user and logs on the new user.
Editing Features
Entering Commands
A CLI command is a series of keywords and arguments. Keywords identify a command, and arguments specify
configuration parameters. For example, in the command
show interfaces status ethernet 1/11
,
show
,
interfaces
and
status
are keywords,
ethernet
is an argument that specifies the interface type, and
1/11
specifies
the port.
To enter commands that require parameters, enter the required parameters after the command keyword. For
example, to set a password for the administrator, enter:
Console(config)#
username
admin
password
alansmith
When working with the CLI, the command options are not displayed. The command is not selected from a menu,
but is manually entered. To see what commands are available in each mode or within an interface configuration,
the CLI does provide a method of displaying the available commands, the command syntax requirements and in
some instances parameters required to complete the command. The standard command to request help is
?
.
There are two instances where help information can be displayed:
Summary of Contents for DXS-3227 - xStack Switch - Stackable
Page 12: ...Page 11 ...
Page 46: ...ACL Commands Page 45 ...
Page 68: ...Address Table Commands Page 67 ...
Page 124: ...Ethernet Configuration Commands Page 123 ...
Page 134: ...GVRP Commands Page 133 ...
Page 144: ...IGMP Snooping Commands Page 143 ...
Page 158: ...IP Addressing Commands Page 157 Console config ip helper address 172 16 9 9 49 53 ...
Page 166: ...IP Addressing Commands Page 165 ...
Page 186: ...Line Commands Page 185 ...
Page 194: ...Management ACL Commands Page 193 ...
Page 200: ...PHY Diagnostics Commands Page 199 ...
Page 208: ...Port Monitor Commands Page 207 ...
Page 216: ...Power over Ethernet Commands Page 215 ...
Page 272: ...RMON Commands Page 271 ...
Page 334: ...Spanning Tree Commands Page 333 ...
Page 428: ...VLAN Commands Page 427 ...
Page 466: ...802 1x Commands Page 465 ...