118
ERROR
SATA PRD mem fail
Failed to init SATA PRD memory manager
ERROR
SATA revision id fail Failed to get SATA revision id
ERROR
SATA set reg fail
Failed to set SATA register
ERROR
SATA init fail
Core failed to initialize the SATA adapter
ERROR
SATA diag fail
SATA Adapter diagnostics failed
ERROR
Mode ID fail
SATA Mode ID failed
ERROR
SATA chip count
error
SATA Chip count error
INFO
SAS port reply error SAS HBA port <number> reply terminated abnormally
INFO
SAS unknown port
reply error
SAS frontend reply terminated abnormally
INFO
FC port reply error
FC HBA port <number> reply terminated abnormally
INFO
FC unknown port
reply error
FC frontend reply terminated abnormally
EMS events
Level Type
Description
INFO
Power install
Power(<string>) is installed
ERROR
Power absent
Power(<string>) is absent
INFO
Power restore
Power(<string>) is restored to work.
ERROR
Power fail
Power(<string>) is not functioning
WARNING Power detect
PSU signal detection(<string>)
INFO
Fan restore
Fan(<string>) is restored to work.
ERROR
Fan fail
Fan(<string>) is not functioning
INFO
Fan install
Fan(<string>) is installed
ERROR
Fan not present
Fan(<string>) is not present
ERROR
Fan over speed
Fan(<string>) is over speed
WARNING Thermal level 1
System temperature(<string>) is higher.
ERROR
Thermal level 2
System Overheated(<string>)!!!
ERROR
Thermal level 2
shutdown
System Overheated(<string>)!!! The system will auto-
shutdown immediately.
ERROR
Thermal level 2
CTR shutdown
The controller will auto shutdown immediately, reason
[ Overheated(<string>) ].
WARNING Thermal ignore
value
Unable to update thermal value on <string>
WARNING Voltage level 1
System voltage(<string>) is higher/lower.
ERROR
Voltage level 2
System voltages(<string>) failed!!!
ERROR
Voltage level 2
shutdown
System voltages(<string>) failed!!! The system will auto-
shutdown immediately.
ERROR
Voltage level 2 CTR
shutdown
The controller will auto shutdown immediately, reason
[ Voltage abnormal(<string>) ].
INFO
UPS OK
Successfully detect UPS
WARNING UPS fail
Failed to detect UPS
ERROR
UPS AC loss
AC loss for system is detected
ERROR
UPS power low
UPS Power Low!!! The system will auto-shutdown
immediately.
WARNING SMART T.E.C.
Disk <slot> S.M.A.R.T. Threshold Exceed Condition occurred
for attribute <string>
WARNING SMART fail
Disk <slot>: Failure to get S.M.A.R.T information
WARNING RedBoot failover
RedBoot failover event occurred
WARNING Watchdog
shutdown
Watchdog timeout shutdown occurred
WARNING Watchdog reset
Watchdog timeout reset occurred