DES-3550 Layer 2 Fast Ethernet Switch
config system_severity
Purpose
To configure severity level of an alert required for log entry or trap message.
Syntax
config system_severity [trap | log | all] [critical | warning | information]
Description
This command is used to configure the system severity levels on the Switch. When
an event occurs on the Switch, a message will be sent to the SNMP agent (trap), the
Switch’s log or both. Events occurring on the Switch are separated into three main
categories, these categories are NOT precisely the same as the parameters of the
same name (see below).
•
Information – Events classified as information are basic events occurring on
the Switch that are not deemed as problematic, such as enabling or disabling
various functions on the Switch.
•
Warning - Events classified as warning are problematic events that are not
critical to the overall function of the Switch but do require attention, such as
unsuccessful downloads or uploads and failed logins.
•
Critical – Events classified as critical are fatal exceptions occurring on the
Switch, such as hardware failures or spoofing attacks.
Parameters
Choose one of the following to identify where severity messages are to be sent.
•
trap –
Entering this parameter will define which events occurring on the Switch
will be sent to a SNMP agent for analysis.
•
log –
Entering this parameter will define which events occurring on the Switch
will be sent to the Switch’s log for analysis.
•
all –
Entering this parameter will define which events occurring on the Switch
will be sent to a SNMP agent and the Switch’s log for analysis.
Choose one of the following to identify what level of severity warnings are to be sent
to the destination entered above.
•
•
•
critical –
Entering this parameter along with the proper destination, stated
above, will instruct the Switch to send only critical events to the Switch’s log or
SNMP agent.
warning –
Entering this parameter along with the proper destination, stated
above, will instruct the Switch to send critical and warning events to the
Switch’s log or SNMP agent.
information
– Entering this parameter along with the proper destination, stated
above, will instruct the switch to send informational, warning and critical events
to the Switch’s log or SNMP agent.
Restrictions Only
administrator-level users can issue this command.
Example usage:
90
Summary of Contents for DES-3550
Page 2: ......
Page 99: ...DES 3550 Layer 2 Fast Ethernet Switch 95 ...