Digital Input/Digital Output
This section allows you to control the behavior of digital input (DI) and digital output (DO) devices. The I/O connector provides the physical
interface for DO and DI that is used for connecting a number of external alarm devices, like IR-Sensors and alarm relays. The digital input is used for
connecting external alarm devices. Once the alarm is triggered, images are recorded and sent by e-mail.
D/I and D/O
Active State:
The camera sends a signal when an event is
triggered, depending upon the status type selected.
N.C.
stands for
Normally Closed
. This means that
the normal state of the circuit is closed. Therefore
events are triggered when the device status
changes to
Open
.
N.O.
stands for
Normally Open.
This means that
the normal state of the circuit is open. Therefore
events are triggered when the device status
changes to
Closed
.
Click