background image

 

NOTE: To control the function in a working station, need to collocate together with optional Chassis 

System and Management Module. 

 

LED Indicator 

The LED indicators give you instant feedback on status of the 
converter:   

 

 

 

LEDs 

State 

Indication 

Power 

(PW R) 

Lights on 

Power on 

Lights off 

Power off 

Link and 

Activity 

(LINK/ACT)

 

Lights on 

Linking   

Lights Blinking 

Data transmitting and receiving 

Lights off 

Not Linking 

 
 

Link Pass Through Function 

LLCF (Link Loss Carry Forward)   

When a device connected to the converter and the TP line loss 
the link, the converter’s fiber will disconnect the link of 
transmit, so that the other ends will know that there is a 
linkage error on this end. And when the Fiber line loss the 
link, the converter’s TP will disconnected, and the other end 
will know that there is linkage problem exist. 
 
There is a default LLCF setting on this converter. 

Summary of Contents for 1000BASE-TX to 1000BASE-SX/LX Media Converter

Page 1: ...1000BASE TX to 1000BASE SX LX Media Converter User s Guide RECYCLABLE 19071001TSC6002 Rev 1 00 ...

Page 2: ... MEDIA CONVERTER 3 PRODUCT FEATURES 4 INSTALLATION 5 SELECTING A SITE FOR THE EQUIPMENT 5 CONNECTING TO POWER 5 INSTALLING IN A CHASSIS 5 MONITORING THE CONVERTER THROUGH MANAGEMENT MODULE 6 LED INDICATOR 7 LINK PASS THROUGH FUNCTION 7 SWITCH 9 SPECIFICATIONS 10 ...

Page 3: ...t Ethernet Media Converter The Converter introduced here provides one channel media conversion between 1000BASE TX and 1000BASE FX About Media Converter Media Converter is a network technology specified by IEEE 802 3ab and IEEE 802 3z 1000BASE TX FX standards ...

Page 4: ...E FX Fiber media allows multi mode fiber and single mode fiber using SC connector Link Pass Through function Auto negotiation of duplex mode on TX port Auto MDI MDI X for TX port Full wire speed forwarding rate Front panel status LEDs Used as a stand alone device or with a chassis Hot swappable when used with a chassis ...

Page 5: ...g 3 Surrounding electrical devices should not exceed the electromagnetic field RFC standards for IEC 801 3 Level 2 3V M field strength 4 Make sure that the equipment receives adequate ventilation Do not block the ventilation holes on each side of the switch or the fan exhaust port on the side or rear of the equipment 5 The power outlet should be within 1 8 meters of the switch Connecting to Power ...

Page 6: ... screw to secure it Monitoring the Converter through Management Module There is a management module that can control this media converter through the chassis system this media converter can be controlled through Web Browser SNMP and terminal emulation program The management module will detect the default reset on the DIP switches and display out the status also the management module can control th...

Page 7: ...inking Lights Blinking Data transmitting and receiving Lights off Not Linking Link Pass Through Function LLCF Link Loss Carry Forward When a device connected to the converter and the TP line loss the link the converter s fiber will disconnect the link of transmit so that the other ends will know that there is a linkage error on this end And when the Fiber line loss the link the converter s TP will...

Page 8: ... Off Off Off Cable 5 Off Off Off Off LLR Link Loss Return When a device connected to the converter and the fiber line loss the link the converter s fiber will disconnect the link of transmit There is a switch to enable or disable the function of the media converter The table below shows how LLR function is working Media Converter LLR Auto Negotiation A ON OFF B OFF OFF Fib e r Co p p e r T X RX Gi...

Page 9: ...R enable Off LLR disable Switch There is a two pin DIP switch on the module which define as switch 1 and switch 2 Switch 1 Fiber mode switch When the switch was turned to On it means that the fiber was turned to forced mode and Off for auto negotiation mode Note Be sure the opposite end is using the same setting forced or Auto negotiation And when using two converters at the same time the two conv...

Page 10: ...er optic cable up to 220m 50 125μm multi mode fiber optic cable up to 550m 1000BASE LX 62 5 125μm multi mode fiber optic cable up to 550m 10 125μm single mode fiber optic cable DMC 810SC up to 10km DMC 880SC up to 80km Dimensions L120 W88 H25 mm Weight 305 g Power External power adaptor 7 5V 1 5A Media Interface RJ 45 SC EMI Compatiblity FCC Class B CE Certification Class B VCCI Class B Temperture...

Reviews: