Standard
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
Option -SGI/-SKS
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
GY (- SGI / SKS)
PK (+ SGI / SKS)
Option -BRV
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
GY (-BRV)
PK (n.c.)
Option -SA/-SZ
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
GY (-SA / -SZ)
PK (-SA / -SZ)
Pin Assignment
The connecting cable is directly connected
to the drive and not changeable.
Shift of drive cable
The drive will be full configured by factory.
The drives must be reconfigured in case of
alterations (e.g. removing of drives
from existing set or integrating
a new drive) with SW-BSY+.
If after mounting the measure x is as bigger as
23 mm, null balance with software SW-BSY+ is
neccesary.
Closure Ranges will shift in relation to new zero
point.
Mount the drives mechanical stress-free.
With that, a better load distribution
is ensured on all the drives.
At vertical active pulling application (e.g. for a
skylight) the forces must be rearranged by software
SW-BSY+
Slave 1
Slave 1
Mounting informations
≥ 23 mm ?
X
1
2
ON
KS
DIP-Switch
Only for ex-works programming.
Debe ser encendido OFF.
Connection: page 18 - 19
KA-BSY+
7/20
English
99.823.89 2.1/07/11