7/16
English
FRA 11-BSY+
99.823.20 2.2/10/12
Mounting informations
3
4
2
+
1
closed and
locked
tilting
position
turning position
hinge on the left
turning position
hinge on the right
LED status display
Emergency unlocking
The window can be manually opened with FRA 11-BSY+ in case of power failure. For this, the FRA11-BSY+ -
drive unit with housing will be unlatched from the base plate and swivelled over the square shaft in the fitting
gear like a normal hand lever. In case of power failure or if an emergency unlocking will be carried out, the
drive will store its „ACTUAL" position.
Attention! Observe after manual emergency operation, that fitting and motor position (position indicator) are
equal to each other, with renewed putting on of FRA 11-BSY+ to the square shaft. (see above)
Window drive
Mot. a and Mot. b
1.5 A
Window
- D+H drives as shown in the table on page 8
can be connected
-
might be loaded with
only,
with drives without BSY+ function
- The window (and the drive) must be locked for
mounting of FRA 11-BSY+
- The window must not be buckled
- The window must be vertically integrated in soffit
- The window wing must close evenly at all
four sides
Fitting
Attention!
Attention!
- Check profile depth of window sash and adjust
square shaft, if necessary, by using lock washer
- The fitting must be easy-running
– Precise adjustment of the pivot- or
side-/pivot- hung window fitting is precondition
for perfect functioning (torque window olive
max. 8 Nm)
- Observe opening width of the side-/ pivot-hung
window fitting in tilting position; stroke of
connected drive must be smaller than opening
width of fitting.
- In the delivery status the square shaft is in the
„locking" (0°) position
– Should the position of the square shaft
be misaligned (e.g. for testing) the drive must be
moved back to „lock" position before mounting
Position indicator
The position indication at the pushbutton of the drive
symbolizes the position of the fitting. The position of
the marking is comparable with the position of a
normal window handle.
Drive status
LED display
Moves from every position
to tilting position
Closes from every position
off
flashes green
flashes red
If CLOSED position reached
If OPEN position reached
lights green for 5 sec.
In case of malfuction
flashes yellow