D+H DYER ZA 35-BSY+ Instructions Manual Download Page 7

Aderbelegung Stecker / Pin Assignment / Brochage des fiches / Asignación de cables

Anschluss / Connection / Connexion / Conexión

(WH) weiss  / white  / blanc   / blanco
(BN)  braun  / brown  / brun   / marrón
(OG) orange / orange / orange / naranja
(YE)  gelb 

/ yellow  / jaune  / amarillo

(GN)  grün 

/ green  / vert  

/ verde

(PK)  rosa 

/ pink 

/ rose   / rosa

(GY)  grau 

/ grey 

/ gris  

/ gris

Option / Opción
-SA-SZ

WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)

GY (-SZ)
GN (-SZ)
PK (-SA)
YE (-SA)
WH (n.c.)
BN (n.c.)
OG (n.c.)

max. 50 V / 0,5 A

s

r

ZA-BSY+

 

ZA-BSY+

18/20

Deutsch / English 

99.824.31 1.4/04/16

Connection 

?

1

2

3

4

5

L

6

N–

7

Z

A E/X

a

b

LT

Group

Mot. a

Mot. b

MOT

(BK)

(BK)

(OG)

2x47k

W

Endmodul

Terminal module

Module terminal

EM 47 K *

(WH)

(WH)

(BN)

(BN)

(OG)

(OG)

(YE)

(YE)

(GN)

(GN)

Mot. a

Mot. a

Mot. b

Mot. b

HS

HS

Data a

Data a

Data b

Data b

ZA-BSY+

ZA-BSY+

Slave(s)

Master 

J

unction box

****

***

**

**

Mot. b 

(BN)

 Mot. a 

(WH)

to control panel 

Monitoring

Normal mode 

SHEV- fast running 

High-Speed

High-Speed

***

High-Speed

*

 

Not in case of GVL -E/ -K/ -M

** 

Pr

otect against short circuit 

*** 

In case of connection to D+H SHEV control panels with E/HS line monitoring 

****  Cable acc. to D+H table for layout of cables (see instructions for use of control panel)

Option / Opción
-BRV

WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)

GY (-BRV)
PK (n.c.)

Standard /
Estándar

WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)

Option / Opción
-SGI

WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)

GY (-SGI)
PK (+SGI)

Option / Opción
-SKS

WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)

GY (SKS)
PK (SKS)

Option / Opción
-SZ

WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)

GY (-SZ)
PK (-SZ)

max. 50 V / 0,5 A

s

Option / Opción
-SA

WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)

GY (-SA)
PK (-SA)

r

max. 50 V / 0,5 A

zweites Anschlußkabel /
second connecting cable /
second câble de raccordement /
segundo cable de conexión

Summary of Contents for DYER ZA 35-BSY+

Page 1: ...Standard version Version without tube option OT Please order bracket sets separately B 08 11 22802 026 G 500001 ZA 35 85 105 155 BSY HS instructions...

Page 2: ...load of the toothed rack is not automatically identical with maximum pressure force of the drive Loads from over 1000 N to 1500 N are only briefly permissible e g to throwing off snow or with wind lo...

Page 3: ...1 2 A 1 0 A 2 0 A 1 2 A 2 2 A 1 4 A 2 5 A Nominal force 300 N 800 N 1000 N 1500 N Nominal locking force 1100 N Lifetime 20 000 double strokes Duty cycle 30 With cycle time 10 minutes Housing Aluminium...

Page 4: ...able Disconnect drive from electric voltage 1 Move out toothed rack about 10 20 mm Disconnect drive from electric Voltage 2 Take off drive unit and shift 3 Attention Moving direction of drive is chang...

Page 5: ...ices that are no longer usable must be collected separa tely and disposed of in an environmentally correct manner Disposal Declaration of Conformity We declare under our sole responsibility that the p...

Page 6: ...a BN Mot b OG HS YE Data A GN Data B GY BRV PK n c Standard WH Mot a BN Mot b OG HS YE Data A GN Data B Option SGI WH Mot a BN Mot b OG HS YE Data A GN Data B GY SGI PK SGI Option SKS WH Mot a BN Mot...

Page 7: ...b HS HS Data a Data a Data b Data b ZA BSY ZA BSY Slave s Master Junction box Mot b BN Mot a WH to control panel Monitoring Normal mode SHEV fast running High Speed High Speed High Speed Not in case o...

Page 8: ...6 0 46 104 9 13 6 30 30 9 7 Version without tube option OT 216 9 13 30 55 Nominal stroke 223 Dyer Environmental Controls Ltd Unit 10 Lawnhurst Trading Estate Cheadle Heath Stockport SK3 0SD Tel 44 0 1...