D+H DYER ZA 35-BSY+ Instructions Manual Download Page 4

A synchron-group (ZA-BSY+) can be count up to 8 
drives, which communicate by a bus. Each drive has 
it’s  own  adress.  This  adress  is  configurable  with 
SCS.
The  last  drive  of  a  synchron-group  is  the  master, 
which controls the other drives, the slaves. Different 
forces between the drives of a group will balanced 
with intelligent force- and position control. In case of 
malfunction respective cutoff of a drive, all drives will 
shut down from the master-drive.

Functional description

ZA-BSY+

 

ZA-BSY+

9/20

English

Visual inspection:

   Only one master-drive allowed.
   The master has, according to common drives,
   the last adress.
   The adress is sticked on the drive. Slaves are 
   nubered downwards.
   Example: In a group, composed of 3 drives,
   there is a master 3, a slave 2 and a slave 1drive.
   Attention: only applies by factory set. as soon as 
   the drives were reprogramized with SCS
   he factory set adressing does not apply any
   longer.

Wiring:

   Is the group wired correctly?
   Therefore look connection diagrams.

Null balance:

   It should be null balanced.
   Software SCS or the special  magnet
   MAG 502 is required.

Call D+H Service:

   Drives must be configured.
   Software SCS is required.

Trouble shooting

99.824.31 1.4/04/16

Mounting examples

Triangular pyramid *

Domelight

Pyramid *

Weighty wing

Uncritical load distribution

Critical load distribution

* Guiding device required by customer in case of complete lift-off of pyramid/domelight,

because of possible lateral load due to wind pressure!

Shifting of drive cable

Disconnect drive from electric voltage!

1. Move out toothed rack about 10 ... 20 mm.

Disconnect drive from electric Voltage!

2. Take off drive unit and shift
3. Attention! Moving direction of drive is changed.

Drive cable on the shutdown pcb, switch
red (+) with black (-)

Shifting of Motor

Mounting informations

- Swivel radius of the drive must go free over entire

range of stroke.  Otherwise, the toothed rack and
the suspension can be damaged

- Drives with a stroke of ≥800 mm must not be moun-

   ted „hung up  at the bottom“ (e.g. bracket UK)

- The drive set will be full configured by factory.

The drives must be reconfigured in case of
alterations (e.g. removing of drives from existing
set or integrating a new drive) with SCS

- Use only drives with the same force.
- Ensure evenly load distribution on all the drives
- Eyebolt has to be adjusted so, that the drive is

disconnected with   closed flap through it’s inside
stop position damping.    Brackets can be damaged
by to rigid adjustment!

10 ... 20 mm

Electrical devices, accessories, batteries and packa-
ging  should  be  sorted  for  environmental-friendly 
recycling.  Do  not  dispose  electrical  devices  and 
batteries into household waste!
Only for EC countries:
According the European Guideline 2012/19/EU for 
waste  electrical  and  electronic  equipment  and  its 
implementation into national right, electrcal devices 
that are no longer usable must be collected separa-
tely  and  disposed  of  in  an  environmentally  correct 
manner.

Disposal

Declaration of Conformity

We  declare  under  our  sole  responsibility  that  the 
product  described  under  “Technical  Data”  is  in 
conformity with the following directives:

2014/30/EU, 2014/35/EU

Technical file at:
D+H Mechatronic AG, D-22949 Ammersbek

Dirk Dingfelder

Maik Schmees

Member of the Board 

Authorized signatory, Technical Director

31.03.2016

Maintenance and cleaning

Maintenance work is only allowed when the device is in
a de-energized condition! Inspection and maintenance 
has to be carried out according to D+H maintenance 
notes.  Only original  D+H  spare  parts  may  be used. 
Repair is to be carried out exclusively by D+H.
Wipe away debris or contamination  with a  dry,  soft 
cloth.
Do not use cleaning agents or solvents.

Guarantee

You will get 2 years guarantee for all D+H products 
from date of verified handing over of the system up to 
maximal  3  years  after  date  of  delivery, when 
mounting  and  starting  has  been  carried  out  by  an 
authorized D+H-distributor.
D+H guarantee is expired, with connection of D+H 
components with external systems or with mixing of 
D+H products with parts of other manufacturers.

Summary of Contents for DYER ZA 35-BSY+

Page 1: ...Standard version Version without tube option OT Please order bracket sets separately B 08 11 22802 026 G 500001 ZA 35 85 105 155 BSY HS instructions...

Page 2: ...load of the toothed rack is not automatically identical with maximum pressure force of the drive Loads from over 1000 N to 1500 N are only briefly permissible e g to throwing off snow or with wind lo...

Page 3: ...1 2 A 1 0 A 2 0 A 1 2 A 2 2 A 1 4 A 2 5 A Nominal force 300 N 800 N 1000 N 1500 N Nominal locking force 1100 N Lifetime 20 000 double strokes Duty cycle 30 With cycle time 10 minutes Housing Aluminium...

Page 4: ...able Disconnect drive from electric voltage 1 Move out toothed rack about 10 20 mm Disconnect drive from electric Voltage 2 Take off drive unit and shift 3 Attention Moving direction of drive is chang...

Page 5: ...ices that are no longer usable must be collected separa tely and disposed of in an environmentally correct manner Disposal Declaration of Conformity We declare under our sole responsibility that the p...

Page 6: ...a BN Mot b OG HS YE Data A GN Data B GY BRV PK n c Standard WH Mot a BN Mot b OG HS YE Data A GN Data B Option SGI WH Mot a BN Mot b OG HS YE Data A GN Data B GY SGI PK SGI Option SKS WH Mot a BN Mot...

Page 7: ...b HS HS Data a Data a Data b Data b ZA BSY ZA BSY Slave s Master Junction box Mot b BN Mot a WH to control panel Monitoring Normal mode SHEV fast running High Speed High Speed High Speed Not in case o...

Page 8: ...6 0 46 104 9 13 6 30 30 9 7 Version without tube option OT 216 9 13 30 55 Nominal stroke 223 Dyer Environmental Controls Ltd Unit 10 Lawnhurst Trading Estate Cheadle Heath Stockport SK3 0SD Tel 44 0 1...

Reviews: