6
G ENERAL MOTOR LAYOUT
Main P.C.Board
(
Marker / m agnetic sensor
Com pact 500 ONLY)
12V D/C
Electric m otor
Charge L.E.D.
GREEN (Com pact 500 only )
Low battery L.E.D.
RED (Com pact 500 only)
Clear gearbox lid
Over-ride access door with lock
Foundation
plate
Jack –up bolts and nuts used to
secure the m otor to the foundation
plate
Holes in plate for conduit access
4 Holes for m ounting
the plate to the concrete
using coach screws
The pictures below show the Com pact 500 and the Com pact 300 m otors. The lids have been rem oved to show greater
detail. The Com pact 500 and Com pact 300 share the sam e maj or com ponents. The differences are shown in the pictures.
The Com pact 500 is shown with the battery rem oved. The foundation plate, base, gearbox, electric m otor, battery ,
P.C.Board and the lid are all shared parts by both m otors.
The Com pact 500 and the Com pact 300 share the sam e foundation plate as shown here
Battery
L.C.D. screen
(Com pact 300 only)
Compact 500
Compact 300
23
NB
the
normally open (NO)
connector is wired to the
TRIG
or
PED
connector on the Main P.C.Board
Receiver board
To program rem otes to the receiver.
1.
Press and hold the button on the rem ote.
2.
Place the j um per over the two TX LEARN pins for 1 second.
3.
Rem ove the j um per.
4.
Release the button on the rem ote.
Repeat the above steps for each rem ote to be programm ed.
Connect to
TRIG for full
opening or
connect to
PED for
pedestrian
opening
Bridge com and neg
CONNECTING AN EXTERNAL RECEIVER (OPTIONAL)
Main P.C.Board