EN / CZone® Control 1
18
5. Connect DC Negative
1. Connect a 2.5mm² (12AWG) cable from the battery negative terminal or main negative bus to the Control
1
’s M6 negative stud.
6. Connect DC Positive
1. Connect an appropriately sized and fused cable from the battery positive terminal to the Control 1
’s M8
positive stud.
2. The positive cable must be of sufficient size to carry the maximum current of all loads connected to the
Control 1 and have a fuse/circuit breaker rated to protect the cable, volt drop should be kept to a
minimum.
3. Maximum recommended cable size is 70mm² (2/0). Cables larger than 70mm² (2/0) should be connected
to a positive stud first with a link to the Control 1.
4. It is possible to conne
ct two positive cables “back to back” on the positive stud for linking the supply on 2
or more Control 1
’s.