PLANNING
•
Make a list of all inputs and outputs to be wired to the Control 1 and take note of the output channel ratings
and functions as shown in Figure 6. Ensure loads are wired to the appropriate channel for the functionality
required.
•
All 25A channels have the option to alarm on detection of external voltage, useful for circuits such as Bilge
Pumps with an external or “automatic” supply from a float switch. This feature reduces wiring by allowing
control and feedback from a single wire. See Figure 7 for a Bilge Pump wiring example.
•
For loads with a continuous current exceeding max channel current it is possible to parallel output channels
up to 80A for OUT-H connector and 100A for OUT-L connector (do not parallel outputs between connectors).
Plug
Position
Max
Current
External
Alarm
Light
Dimming
Output 1
OUT-H 1
25A
✓
Output 2
OUT-H 2
25A
✓
Output 3
OUT-H 3
25A
✓
Output 4
OUT-H 4
25A
✓
Output 5
OUT-L 1
10A
✓
Output 6
OUT-L 2
10A
✓
Output 7
OUT-L 3
10A
✓
Output 8
OUT-L 4
10A
✓
Output 9
OUT-L 5
10A
✓
Output 10
OUT-L 6
10A
✓
Output 11
OUT-L 7
10A
✓
Output 12
OUT-L 8
10A
✓
Output 13
OUT-L 9
10A
✓
Output 14
OUT-L 10
10A
✓
Output 15
OUT-L 11
10A
✓
Output 16
OUT-L 12
10A
✓
Figure 6. Output Channel Specifications
Figure 7. Control 1 Bilge Pump Wiring Example