Document Number: 002-10635 Rev. *I
Page
185 of 325
S6J3310/20/30/40 Series
9.1.4.3
Internal Clock Timing (S6J3310)
This chapter shows the TARGET characteristics for internal clock timing at the current stage.
In the column symbol, same clock names as described in CHAPTER 5: CLOCK SYSTEM of
Traveo
TM
Platform Hardware
Manual
are used.
Corresponding functions for these clocks are described in CHAPTER 5: CLOCK CONFIGURATION of
S6J3300 Series
Hardware Manual
.
(T
A
: Recommended operating conditions, V
CC
5 = 5.0 V ±10 %, V
CC
12 = 1.15 V ± 0.06 V, V
SS
= 0.0 V)
Parameter
Symbol
Value
Unit
Remarks
Max *1
Max *2
Max *3
Internal clock
frequency
F
SSCG0
480
400
360
MHz
SSCG0 output clock *4
F
SSCG1
400
400
400
MHz
SSCG1 output clock *4
F
SSCG2
320
320
320
MHz
SSCG2 output clock *4
F
SSCG3
400
400
400
MHz
SSCG3 output clock *4
F
PLL0
480
400
360
MHz
PLL0 output clock *4
F
PLL1
400
400
400
MHz
PLL1 output clock *4
F
PLL2
400
400
400
MHz
PLL2 output clock *4
F
PLL3
480
480
480
MHz
PLL3 output clock *4
F
CLK_CPU0
240
200
180
MHz
F
CLK_SHE
240
200
180
MHz
F
CLK_FCLK
80
66.7
90
MHz
F
CLK_ATB
120
100
90
MHz
F
CLK_DBG
120
100
90
MHz
F
CLK_HPM
120
200
180
MHz
F
CLK_HPM2
60
100
90
MHz
F
CLK_DMA
120
200
180
MHz
F
CLK_MEMC
120
200
180
MHz
F
CLK_EXTBUS
40
40
30
MHz
F
CLK_SYSC1
40
40
60
MHz
F
CLK_HAPP0A0
40
40
30
MHz
Unused
F
CLK_HAPP0A1
40
40
30
MHz
Unused
F
CLK_HAPP1B0
80
50
60
MHz
F
CLK_HAPP1B1
40
50
30
MHz
Unused
F
CLK_LLPBM
240
200
180
MHz
F
CLK_LLPBM2
120
100
90
MHz
F
CLK_LCP
80
50
60
MHz
F
CLK_LCP0
40
40
30
MHz
F
CLK_LCP0A
80
66.7
60
MHz
F
CLK_LCP1
40
40
30
MHz
Unused
F
CLK_LCP1A
80
66.7
60
MHz
F
CLK_LAPP0
40
40
30
MHz
Unused
F
CLK_LAPP0A
40
40
30
MHz
Unused
F
CLK_LAPP1
40
40
30
MHz
Unused
F
CLK_LAPP1A
40
40
30
MHz
Unused
F
CLK_TRC
100
100
100
MHz
F
CLK_CD1
200
200
200
MHz
F
CLK_CD1A0
100
100
100
MHz
Unused
F
CLK_CD1A1
100
100
100
MHz
Unused
F
CLK_CD1B0
100
100
100
MHz
Unused
F
CLK_CD1B1
100
100
100
MHz
Unused
F
CLK_CD2
200
200
200
MHz
Unused
F
CLK_CD2A0
200
200
200
MHz
F
CLK_CD2A1
200
200
200
MHz
Unused
F
CLK_CD2B0
200
200
200
MHz
Unused
F
CLK_CD2B1
200
200
200
MHz
Unused
F
CLK_CD3
80
80
80
MHz
Unused
F
CLK_CD3A0
80
80
80
MHz
F
CLK_CD3A1
80
80
80
MHz
Unused