Kit Operation and PLC Control Panel GUI
7. In the Local Node tab, choose a unique logical address for the node.
Figure 3-7. Local Node Tab
8. Set RX Gain to
250 µV
. All other drop-down menus can be left with their default values.
9. Enable the transmitter by checking
Enable Transmitter
.
10.Enable the receiver by checking
Enable Receiver
.
11. Select
Overwrite at Receiver
.
12.Click on
Set Configuration
. This writes the configuration into the PLC node. To verify, click on
Get Configuration
; the configuration values remain as they were set. If either of these
commands are not successful, an error message is displayed.
13.Perform steps (1) to (10) for the second node. This node must be given a different logical address
than the first node.
14.To send and receive messages between the boards, click on the Messaging tab in both GUIs.