4. Once the project is opened in PSoC Designer, build the project by clicking
Build > Generate/Build Project
. The project should build with 0 errors and 0 warnings.
5. In the menu, click Program > Program Part. This will open the Program Part window.
6. Set the “Acquire Mode” property as “Reset”, and press the “Toggle Power” button to power ON
the board. (The “toggle power” button need not be pressed if the board is already connected and
powered through the power line.)
Figure 5-7. Programming Settings
7. Click the arrow in the bottom right corner to start programming. After the progress bar is
complete, the status should say ‘Programming Successful’.
8. Remove the MiniProg from the ISSP header and press the RESET pushbutton to reset the
device.
9. Repeat the above steps to program another board.