CY7C1141V18, CY7C1156V18
CY7C1143V18, CY7C1145V18
Document Number: 001-06583 Rev. *D
Page 21 of 28
Maximum Ratings
Exceeding maximum ratings may shorten the useful life of the
device. User guidelines are not tested.
Storage Temperature ................................ –65°C to + 150°C
Ambient Temperature with Power Applied. –55°C to + 125°C
Supply Voltage on V
DD
Relative to GND .......–0.5V to + 2.9V
Supply Voltage on V
DDQ
Relative to GND ..... –0.5V to + V
DD
DC Applied to Outputs in High-Z ........ –0.5V to V
DDQ
+ 0.3V
DC Input Voltage
[13]
.............................–0.5V to V
DDQ
+ 0.3V
Current into Outputs (LOW)......................................... 20 mA
Static Discharge Voltage (MIL-STD-883, M. 3015).. > 2001V
Latch up Current.................................................... > 200 mA
Operating Range
Range
Ambient
Temperature (T
A
)
V
DD
[17]
V
DDQ
[17]
Commercial
0°C to +70°C
1.8 ± 0.1V
1.4V to
V
DD
Industrial
–40°C to +85°C
Electrical Characteristics
The DC Electrical Characteristics over the operating range follows.
[14]
Parameter
Description
Test Conditions
Min
Typ
Max
Unit
V
DD
Power Supply Voltage
1.7
1.8
1.9
V
V
DDQ
IO Supply Voltage
1.4
1.5
V
DD
V
V
OH
Output HIGH Voltage
Note 18
V
DDQ
/2 – 0.12
V
DDQ
/2 + 0.12
V
V
OL
Output LOW Voltage
Note 19
V
DDQ
/2 – 0.12
V
DDQ
/2 + 0.12
V
V
OH(LOW)
Output HIGH Voltage
I
OH
=
−
0.1 mA, Nominal Impedance
V
DDQ
– 0.2
V
DDQ
V
V
OL(LOW)
Output LOW Voltage
I
OL
= 0.1 mA, Nominal Impedance
V
SS
0.2
V
V
IH
Input HIGH Voltage
V
REF
+ 0.1
V
DDQ
+ 0.15
V
V
IL
Input LOW Voltage
–0.15
V
REF
– 0.1
V
I
X
Input Leakage Current
GND
≤
V
I
≤
V
DDQ
−
2
2
μ
A
I
OZ
Output Leakage Current
GND
≤
V
I
≤
V
DDQ,
Output Disabled
−
2
2
μ
A
V
REF
Input Reference Voltage
[20]
Typical Value = 0.75V
0.68
0.75
0.95
V
I
DD
[21]
V
DD
Operating Supply
V
DD
= Max, I
OUT
= 0 mA,
f = f
max
= 1/t
CYC
300 MHz
663
mA
333 MHz
708
mA
375 MHz
766
mA
I
SB1
Automatic Power Down
Current
Max V
DD
,
Both Ports Deselected,
V
IN
≥
V
IH
or V
IN
≤
V
IL
f = f
max
=1/t
CYC
,
Inputs Static
300 MHz
201
mA
333 MHz
212
mA
375 MHz
227
mA
AC Electrical Characteristics
The AC Electrical Characteristics over the operating range follows.
[13]
Parameter
Description
Test Conditions
Min
Typ
Max
Unit
V
IH
Input HIGH Voltage
V
REF
+ 0.2
–
V
DDQ
+ 0.24
V
V
IL
Input LOW Voltage
–0.24
–
V
REF
– 0.2
V
Notes
17. Power up: Is based on a linear ramp from 0V to V
DD
(min) within 200 ms. During this time V
IH
< V
DD
and V
DDQ
< V
DD
.
18. Output are impedance controlled. I
OH
=
−
(V
DDQ
/2)/(RQ/5) for values of 175
Ω
<= RQ <= 350
Ω
.
19. Output are impedance controlled. I
OL
= (V
DDQ
/2)/(RQ/5) for values of 175
Ω
<= RQ <= 350
Ω
.
20. V
REF
(min) = 0.68V or 0.46V
DDQ
, whichever is larger, V
REF
(max) = 0.95V or 0.54 V
DDQ
, whichever is smaller.
21. The operation current is calculated with 50% read cycle and 50% write cycle.
[+] Feedback
[+] Feedback