36
COMMAND
Description and Parameters
SET EDID N1 NAME N2
Set the name for the specified EDID.
N1
= 7~14
[EDID number]
N2
= {EDID Name}
[32 characters max]
Note: Only User EDIDs may be renamed.
GET EDID N1 NAME
Show the name for the specified EDID.
N1
= 1~22
[EDID Number]
GET INTERNAL N1 EDID DATA
Show the specified Internal EDID as hex data.
N1
= 1~6
[Internal EDID number]
SET USER N1 EDID DATA N2
Upload a new EDID (in hex format) for use as the specified User
EDID.
N1
= 1~8
[User EDID number]
N2
= {Hex Data}
[EDID data]
Note: The data block is comma delimited ASCII hex pairs and
cannot contain any spaces.
GET USER N1 EDID DATA
Show the current contents of the specified User EDID as hex data.
N1
= 1~8
[User EDID number]
GET SINK N1 EDID DATA
Show the EDID from the display connected to the specified out
-
put as hex data.
N1
= A~H
[Output port]
GET IN N1 EDID DATA
Show the EDID currently used by the specified input as hex data.
N1
= 1~8
[Input port]