![CYP CH-2603RX Operation Manual Download Page 25](http://html.mh-extra.com/html/cyp/ch-2603rx/ch-2603rx_operation-manual_2705435025.webp)
20
COMMAND
Description and Parameters
set webgui login timeout
N1
Set the WebGUI inactivity timeout value.
Available values for
N1
:
0 [No timeout]
1 ~ 65535
[Timeout in minutes]
get webgui login timeout
Show the current WebGUI inactivity
timeout value.
set in N1 name N2
Set the name of the specified input.
N1
= 1 ~ 2
[Input port]
N2
= {Name}
[
16 characters max
]
get in N1 name
Show the current name of the specified
input.
N1
= 1 ~ 2
[Input port]
set out N1 name N2
Set the name of the specified output.
N1
= A ~ B
[
Output port
]
N2
= {Name}
[
16 characters max
]
get out N1 name
Show the name of the specified output.
N1
= A ~ B
[
Output port
]
set out N1 route N2
Set the routing of the specified output.
N1
= A ~ B
[
Output port
]
N2
= 1 ~ 2
[Input port]