24
COMMAND
DESCRIPTION AND PARAMETERS
set automation event N1
cec A N2
Enable or disable the specified Automation
Event's CEC response.
Available values for
N1
:
1
[Power on]
2
[Out A source
active]
3
[Out A source lost]
Available values for
N2
:
ON
[Event enabled]
OFF
[Event disabled]
get automation event N1
cec A
Show the current state of the specified
Automation Event's CEC response.
Available values for
N1
:
1
[Power on]
2
[Out A source active]
3
[Out A source lost]
set automation event N1
cec A delay N2
Set the delay time that the specified
Automation Event must continue to be true
before sending the defined CEC command.
Available values for
N1
:
1
[Power on]
2
[Out A source active]
3
[Out A source lost]
N2
= 0 ~ 240
[Delay time in seconds]