INSTALLATION
WIRING DIAGRAM
Important! Heating elements operate at 230V.
Important! For each connection the protective conductor must be connected
to the terminal marked .
Type /
Conductor
cross sec-
tion
Fuse
protec-
tion
1
For a 230 V single phase connec
-
tion with a neutral lead, terminals
L1, L2 are bridged, neutral lead is
connected to terminal N, and the
protective conductor to .
1N~
HO5VV-FG
3X 4 mm
2
min.30 A
2* For a 230/400 V two phase con
-
nection with a neutral lead, neutral
lead is connected to terminal N, and
the protective conductor to .
2N~
HO5VV-FG
4X2,5mm
2
min.16 A
3*
For a 230/400 V two phase con
-
nection with a neutral lead, neutral
lead is connected to terminal N, and
the protective conductor to
3N~
H05VV-FG
5X 1,5 mm
2
min.16 A
4*
Perilex plug with power cord is
supplied with the appliance.
3N~
H05VV-FG
5X 1,5 mm
2
min.16 A
L1=R, L2=S, L3=T; N = neutral lead
connection
;
= protective lead terminal
GY- Gray, BK- Black, BN- Brown, BU- Blue, GNYE- Yellow-Green,
* For domestic 3-phase 230/400 V electrical system, connect the remaining wire to the
terminal:L3, which is not connected to the hob internal electrical system.
* NN terminals are internally connected, they need not be bridged
L1
N
L1
L2
N
L1
L2
N
L3
BN
GY BK
BU
GNYE