3.2. Error E6
Incorrect power connection
Incorrect supply voltage: ……V
Wrong coil for the cooking zone: FL RL RR FR
Cooking zone coil connected incorrectly: FL RL RR FR
NO
YES
Cooking zone sensor connected incorrectly: FL RL RR FR
Damaged IGBT: 1 2 3 4
Damaged varistor
No connection of filter PCB with the module
Replaced induction module
N
O
YES
N
O
YES
N
O
YES
YES
NO
YES
NO
N
O
YES
Check the connection and the voltage on L1 and L2 power
conductors. Point 3.1.
Technician should note all defects found in the
following list:
Are the connections and
voltage correct?
Check varistors. Point 10.6.
Are varistors
operational?
Damage to the varistor is due to
the miswiring of power
conductors or electrical network
overvoltage. - Add the
recommendations consistent
with the service procedure
Check if the four IGBTs are operational. Point
8.
Are IGBTs
operational?
Replace the induction module while paying
special attention to the correct connection of
induction coils and temperature sensors
Inform the client of an incorrect
cooking zone connection or
overvoltage — note the
recommendations according to
the service procedure
Is the connection
correct?
Check the connection between filter PCB and
induction module PCB. Point 10.
Is the connection
correct?
Check if the correct type induction coils are
used. Point 7.
Are correct coils used?
Replace with correct coils.
Check the connection of cooking zone
induction coils and temperature sensors.
Point 10.5.
Replace the module while paying special
attention to the correct connection of
induction coils and temperature sensors
End of repair
Check the correct operation of the hob Point
9.2.
Check the correct operation of the hob Point
9.2.
Check the correct operation of the hob Point
9.2.
Replace the induction module while paying
special attention to the correct connection of
induction coils and temperature sensors
Assemble the hob paying special attention to
the correct connection of induction coils and
temperature sensors
Does the hob operate
correctly?
Summary of Contents for 4VI515 Series
Page 3: ... 3 1 HOB FEATURES AND COMPONENTS ...
Page 13: ... 13 2 single coils 6 dual coils 5 single coils ...
Page 18: ... 18 9 2 Check if neutral conductor for L1 phase is connected correctly ...
Page 19: ... 19 9 3 Check if L1 phase is connected correctly ...
Page 20: ... 20 9 4 Check if L2 phase is connected correctly ...
Page 21: ... 21 9 5 Check if coils are connected correctly ...