Cyfral CC-4000 Operating, Installation And Programming Manual Download Page 7

 

~7~ 

 

 

3.1.3. 

 

In the CC4000 system, the electromagnetic strike is managed by the PC-4000 panel. This subprogram is used to 

configure the main electric strike 

LOCK1. 

Available operation modes: 

 strike released from the first button of the uniphone, proximity key, tenant code   

 strike inactive 

 strike released from the first button of the uniphone, tenant code 

 strike released from 

the first button of the uniphone, proximity key. 

Selecting 

 ends the subprogram operation. Selecting a different option transfers the deceleration time of 

the electric strike within l-15 seconds 

 Then, select the deceleration time using the button for leaving 

the  property  in  the  range  1-15 

.  The  next  field  is  the  operation  mode.  Electromagnetic 

jumper/reversing strike or traditional electric strike.  

Options: 

 Selecting  the  jumper  ends  the  subprogram  operation.  Selection  of  the  strike 

leads to the volume option of the electric strike. The range to choose 1-100 

3.1.4. 

 

The PC-4000 panel has an additional current output that controls an additional output, eg a gate. There are several 

triggering options available. 

 output activated from the second uniphone button, proximity key, tenant code? 

  output inactive 

 output activated from the second uniphone button and tenant code 

output activated 

from  the  second  uniphone  button  and  proximity  key.  Disabling  the  function  ends  the  subprogram  operation, 

otherwise we move on to setting the pulse duration in the range from 0.5s to 10s with a step of 0.5s

3.1.5. 

 

The  function  of  a  built-in  combination  panel.  It  is  an  autonomous  four-digit  code  stored  in  the  panel's  memory, 

independent of the control electronics. It can be used as a shared code for tenants, or as a code for the installer. 

Options  available: 

 inactive  code 

 the  code  activates  the  main  electro-strike 

 

the code activates the additional electro-strike. The next step is to give a four-digit number 

. Accept and 

enter the same number the second number. The combination lock is activated in the panel in idle mode by entering 

from the keypad. 

It is displayed: 

 please enter the code given earlier and then the input assigned to it will be opened. 

 

Summary of Contents for CC-4000

Page 1: ...1 INTERCOM WITH DIGITAL DIALING CC4000 SYSTEM OPERATING INSTALLATION AND PROGRAMMING MANUAL 1v1...

Page 2: ...on 9 3 3 P03 Subscribers 10 3 3 1 Adding a subscriber 10 3 3 2 Deleting a subscriber 10 3 3 3 Simple initialisation of a subscriber table 10 3 3 4 Advanced initialisation of a subscriber table 10 3 3...

Page 3: ...d resistant steel metal backlit mechanical keyboard and an eight digit alphanumeric display with heating The backlight of the display has a day night brightness adjustment Integrated energy saving UNI...

Page 4: ...ality cables DETAILED DESCRIPTION of each of the above mentioned devices is provided within dedicated manuals Detailed technical data connector descriptions technical drawings assembly methods accepta...

Page 5: ...ogramming mode To access the programming mode enter on the keypad the following sequence On the display there will appear a field for entering the serial number of the panel PC 4000 board Enter the se...

Page 6: ...t is currently stored in the panel will be displayed At this point enter the serial number of the control panel with which you want to pair the panel If the control panel is correctly connected and th...

Page 7: ...has an additional current output that controls an additional output eg a gate There are several triggering options available output activated from the second uniphone button proximity key tenant code...

Page 8: ...fob In addition entering the panel programming using such a key fob blocks the ability to reset the panel settings and change the administrator password 3 1 8 Administrator password You must type the...

Page 9: ...30s and confirm with an asterisk 3 2 5 System activity time of the control panel after the end of the call Enables you to start a call after the call is ended within the programmed time After entering...

Page 10: ...ber already exists at the physical address an error will be displayed 3 3 2 Deleting a subscriber Enter the subscriber s number not the physical address that you want to delete in the field and confir...

Page 11: ...he function will appear Set the desired value and confirm with an asterisk 3 3 8 Subscriber table In the first step enter the physical address of the uniphone from which the program starts searching f...

Page 12: ...ory 3 4 7 Restores all subscriber codes to the default values Compatible with the predefined opening code table 3 5 A program for managing electronic keys stored in the control panel memory 3 5 1 Add...

Page 13: ...on to PC 4000 panel supply of power we always use a power cable with a minimum cross section of 1mmA 2 Otherwise there is a risk of incorrect system operation UNIPHONES to the CC 4000 board to the L a...

Page 14: ...each digit pressing If the next digit is selected during this time the program will create the property number from the next digits Attempting to dial a number longer than 4 digits will not change th...

Page 15: ...ning code and wait NOTE 1 The 0 digit in the code is not a significant number if it is at the beginning of the number and can be omitted 2 If the code has been entered correctly the electric striker w...

Page 16: ...d and have the markings VPL VPH and GND We connect them directly to the camera module according to the VPL to L VPH to H GND to GND The strike outputs are connected in accordance with the diagram The...

Page 17: ...EXIT BUTTON STRIKE2 MAIN STRIKE CONTROL ELECTRONICS CC 4000 SUPPLY OF POWER 12V 1A POWER SUPPLY FOR UNIPHONES AND MONITORS CC 4000 ELECTRONICS INTEGRATED IN PANEL...

Page 18: ...in the SLAVE connector matches the order on the panel board 1 1 The strike outputs are connected in accordance with the diagram The main strike can be a jumper strike reversing strike with a maximum c...

Page 19: ...EXIT BUTTON STRIKE2 MAIN STRIKE CONTROL ELECTRONICS CC 4000 SUPPLY OF POWER 12V 1A POWER SUPPLY CC 4000 ELECTRONICS INTEGRATED IN PANEL FOR UNIPHONES...

Page 20: ...d As a rule it should be the electronics to which the connecting cables have the shortest route It should be noted that the MASTER connector on the CC 4000 board does not have a 12V terminal All MASTE...

Page 21: ...Y OF POWER 12V 1A POWER SUPPLY SUPPLY OF POWER 12V 1A POWER SUPPLY CONTROL ELECTRONICS CC 4000 FOR SUBSEQUENT STAIRCASES FOR UNIPHONES AND MONITORS FOR UNIPHONES AND MONITORS MAIN INPUT 1 EXIT BUTTON...

Page 22: ...vice key fob In order to facilitate the installation procedure you can assign an RFID proximity key to the PC 4000 panel The key is assigned to the program in subprogram 7 In order to use the key adde...

Page 23: ...y removing the handset pressing the opening button etc ATTENTION The time required to scan the whole line of 255 uniphones is about 5 minutes which is why it is recommended to narrow the search ranges...

Page 24: ...umber eg 1 confirm with an asterisk and only enter the number of the tenant you are interested in Without using the serial number and system number The BASIC type MASTER panel sends a request to all c...

Page 25: ...tered E14 Short circuit of uniphone line Voltage of uniphone line below 3V E15 Codes do not match When changing the installer passcode different passcodes have been given in two steps E17 Number out o...

Reviews: