Cyfral CC-4000 Operating, Installation And Programming Manual Download Page 5

 

~5~ 

 

 

 

Adjustable separate opening time from the exit button 

 

Reverse operation mode of the strike 

 

Volume control of the electric strike 

 

Gate control 

 

Possibility of personal assignment of the entrance to the combination lock/RFID key 

 

Individual settings for each subscriber 

 

Three ringtone melodies 

 

Increasing ringtone function 

 

Camera illuminated with IR LEDs 

 

camera viewing angle adjustment 

 

Wide-angle camera: 110 degrees 

 

Symmetrical video line 

 

The installation mode facilitates the installation of the system by one person 

 

Search mode for damaged uniphones 

 

All settings can be programmed from a PC 

 

An RFID service key that simplifies system installation 

 

Office opening mode 

 

Quick entry mode to the staircase 

2. P

ROGRAMMING OF

 CC40005 system 

To prepare the system for work, each panel should be paired with the control electronics. 

To do this, enter the PC-4000 panel programming mode. 

To access the programming mode, enter on the keypad the following sequence: 

. On 

the display there will appear a field for entering the 

serial number of the panel (PC-4000 board)

 

 

Enter the serial number and confirm with the key

. Then, the field for entering the installer's password will appear

. Enter the default value 

 and confirm with the key 

If the password and serial number are compatible, on the display there will appear 

 and from that 

moment the panel will be in programming mode. If an incorrect serial number or password has been entered, the 

panel will display the following message: 

3. D

ESCRIPTION OF PROGRAMS

 

There are five main programs from P01 to P05. Each program supports a separate group of settings. In order to 

move between the programs, use the keys "1" and "3". One scrolls programs to the left and three to the right. In order 

to exit completely from programming mode, press . Below there is a detailed description of all programs together with 

their subprograms. If the panel is configured as Master, only the settings in P01 program can be changed. 

 

Summary of Contents for CC-4000

Page 1: ...1 INTERCOM WITH DIGITAL DIALING CC4000 SYSTEM OPERATING INSTALLATION AND PROGRAMMING MANUAL 1v1...

Page 2: ...on 9 3 3 P03 Subscribers 10 3 3 1 Adding a subscriber 10 3 3 2 Deleting a subscriber 10 3 3 3 Simple initialisation of a subscriber table 10 3 3 4 Advanced initialisation of a subscriber table 10 3 3...

Page 3: ...d resistant steel metal backlit mechanical keyboard and an eight digit alphanumeric display with heating The backlight of the display has a day night brightness adjustment Integrated energy saving UNI...

Page 4: ...ality cables DETAILED DESCRIPTION of each of the above mentioned devices is provided within dedicated manuals Detailed technical data connector descriptions technical drawings assembly methods accepta...

Page 5: ...ogramming mode To access the programming mode enter on the keypad the following sequence On the display there will appear a field for entering the serial number of the panel PC 4000 board Enter the se...

Page 6: ...t is currently stored in the panel will be displayed At this point enter the serial number of the control panel with which you want to pair the panel If the control panel is correctly connected and th...

Page 7: ...has an additional current output that controls an additional output eg a gate There are several triggering options available output activated from the second uniphone button proximity key tenant code...

Page 8: ...fob In addition entering the panel programming using such a key fob blocks the ability to reset the panel settings and change the administrator password 3 1 8 Administrator password You must type the...

Page 9: ...30s and confirm with an asterisk 3 2 5 System activity time of the control panel after the end of the call Enables you to start a call after the call is ended within the programmed time After entering...

Page 10: ...ber already exists at the physical address an error will be displayed 3 3 2 Deleting a subscriber Enter the subscriber s number not the physical address that you want to delete in the field and confir...

Page 11: ...he function will appear Set the desired value and confirm with an asterisk 3 3 8 Subscriber table In the first step enter the physical address of the uniphone from which the program starts searching f...

Page 12: ...ory 3 4 7 Restores all subscriber codes to the default values Compatible with the predefined opening code table 3 5 A program for managing electronic keys stored in the control panel memory 3 5 1 Add...

Page 13: ...on to PC 4000 panel supply of power we always use a power cable with a minimum cross section of 1mmA 2 Otherwise there is a risk of incorrect system operation UNIPHONES to the CC 4000 board to the L a...

Page 14: ...each digit pressing If the next digit is selected during this time the program will create the property number from the next digits Attempting to dial a number longer than 4 digits will not change th...

Page 15: ...ning code and wait NOTE 1 The 0 digit in the code is not a significant number if it is at the beginning of the number and can be omitted 2 If the code has been entered correctly the electric striker w...

Page 16: ...d and have the markings VPL VPH and GND We connect them directly to the camera module according to the VPL to L VPH to H GND to GND The strike outputs are connected in accordance with the diagram The...

Page 17: ...EXIT BUTTON STRIKE2 MAIN STRIKE CONTROL ELECTRONICS CC 4000 SUPPLY OF POWER 12V 1A POWER SUPPLY FOR UNIPHONES AND MONITORS CC 4000 ELECTRONICS INTEGRATED IN PANEL...

Page 18: ...in the SLAVE connector matches the order on the panel board 1 1 The strike outputs are connected in accordance with the diagram The main strike can be a jumper strike reversing strike with a maximum c...

Page 19: ...EXIT BUTTON STRIKE2 MAIN STRIKE CONTROL ELECTRONICS CC 4000 SUPPLY OF POWER 12V 1A POWER SUPPLY CC 4000 ELECTRONICS INTEGRATED IN PANEL FOR UNIPHONES...

Page 20: ...d As a rule it should be the electronics to which the connecting cables have the shortest route It should be noted that the MASTER connector on the CC 4000 board does not have a 12V terminal All MASTE...

Page 21: ...Y OF POWER 12V 1A POWER SUPPLY SUPPLY OF POWER 12V 1A POWER SUPPLY CONTROL ELECTRONICS CC 4000 FOR SUBSEQUENT STAIRCASES FOR UNIPHONES AND MONITORS FOR UNIPHONES AND MONITORS MAIN INPUT 1 EXIT BUTTON...

Page 22: ...vice key fob In order to facilitate the installation procedure you can assign an RFID proximity key to the PC 4000 panel The key is assigned to the program in subprogram 7 In order to use the key adde...

Page 23: ...y removing the handset pressing the opening button etc ATTENTION The time required to scan the whole line of 255 uniphones is about 5 minutes which is why it is recommended to narrow the search ranges...

Page 24: ...umber eg 1 confirm with an asterisk and only enter the number of the tenant you are interested in Without using the serial number and system number The BASIC type MASTER panel sends a request to all c...

Page 25: ...tered E14 Short circuit of uniphone line Voltage of uniphone line below 3V E15 Codes do not match When changing the installer passcode different passcodes have been given in two steps E17 Number out o...