Shenzhen Zhiyong Electronics Co., Ltd 

 

5. Machinery Specification 

Type 

Parameter 

Differential input cable 

15cm 

      BNC output cable (CK-310) 

1m 

      Alligator clips (CK-261) 

85*40*17mm 

      Piston clips (CK-281) 

152*50*13mm 

      Test hook (CK-284) 

121*23*23mm 

      Probe dimension 

Front 

116*22*15mm 

Back 

124*49*27mm 

      Probe weight 

172g 

 

6. Environmental Characteristics 

Type 

Parameter 

Pollution level 

Operating temperature 

0

℃~

50

 

Storage temperature 

-30

℃~

70

 

Operating humidity 

≤85%RH 

Storage humidity 

≤90%RH 

Operating altitude 

3000m 

Storage altitude 

12000m 

 

7. Operating Steps 

 

The  range  of  the  voltage  under  test  should  be  estimated  before  the  test.  Voltage  surpassing  the 

measuring range could possibly damage the probe and the product. 

 

Connect the input and output cable to the probe and connect the probe with oscilloscope or other test 

devices. 

 

The green power indicator will be lighted when the power supply adaptor connects with the voltage 

probe.  When  the  voltage  under  test  surpass  the  range,  the  indicator  will  be  lighted  along  with  the 

buzzer. 

 

Set the attenuation ratio of the oscilloscope or other devices to 10:1, input impedance to 50Ω (If the 

probe output port is connected with 50Ω thorough type  load, the input impedance should be 1MΩ) 

Adjust the sensitivity of the oscilloscope according to the voltage under test 

 

Connect  the  clips  according  to  needs  and  start  the  test.  The  main  body  of  the  probe  should  be  put 

away from the high voltage pulse circuit to minimize the interference. 

 

Turn off the power of the circuit under test after the test is over, then turn off the power of the probe 

and    disconnect the two input ports from the point under test, and unplug the BNC connector from 

oscilloscope. 

CYBERTEK

Summary of Contents for DP6020

Page 1: ...Shenzhen Zhiyong Electronics Co Ltd www cybertek cn Low Voltage Differential Probe DP6020 20V 200MHz Shenzhen Zhiyong Electronics Co Ltd CYBERTEK ...

Page 2: ...s off before the probe is plugged in Turn off the circuit and then take off the probe after the testing Make sure the BNC port is well grounded when the probe BNC output cable is connected to the oscilloscope or other devices Check the external surface of the probe before testing If there s any damage upon the probe please stop the usage Power the probe with the standard adapter DP6020 Brief Descr...

Page 3: ...0 Series Brief Description 1 Summary 3 Application 3 Products and Accessories 3 Main Part of Probe 3 Accessories 4 Electrical Specifications 5 Machinery Specification 6 Environment Specifications 6 Operating Steps 6 Maintenance 7 Warranty 7 Packing List 7 CYBERTEK ...

Page 4: ... speed power testing Digital differential bus Vehicle serial bus CAN LIN FlexRay 3 Product and Accessories Product Detailed Instruction Input Cable length around 15cm used to measure the voltage signal Offset Adjust adjust the resistor to realize the adjusting of the output Connecting Cable the connector of the front and back side of the probe length around 70cm Power Supply Port standard USB Type...

Page 5: ...Cable CK 310 USB Cable CK 315 AM BM 1 5m Power Supply Adaptor CK 605 USB 5V 1A Power Accessories Instruction Alligator clips CK 261 CATIII 1000V CATIV 600V Piston clips CK 281 CATIII 1000V Test hook CK 284 CATII 1000V Thorough type 50Ω load CK 50 50Ω 1W Coaxial output cable CK 310 Double ended BNC port coaxial line 1m USB cable CK 315 AM BM 1 5m Power supply adaptor CK 605 USB 5V 1A CYBERTEK ...

Page 6: ...500kΩ Double input 1MΩ Input capacitance Single to earth 7pF Double input 3 5pF Output voltage fluctuation 2V 50Ω Oscilloscope Input Offset Typical value 2mV Offset adjust range Typical value 95mV CMRR 50Hz 60Hz 80dB 10MHz 50dB Noise Vrms 6mV Overload indicator voltage threshold 20V Delay time Probe main 11ns BNC 1m 5ns Overload indicator Indicator will be lighted red when overload occurs Terminal...

Page 7: ...e probe and connect the probe with oscilloscope or other test devices The green power indicator will be lighted when the power supply adaptor connects with the voltage probe When the voltage under test surpass the range the indicator will be lighted along with the buzzer Set the attenuation ratio of the oscilloscope or other devices to 10 1 input impedance to 50Ω If the probe output port is connec...

Page 8: ...ty card 10 Packing List Packing List Voltage probe 1 USB 5V 1A adaptor CK 605 1 Alligator clips CK 261 1 Insulated piston clips CK 281 1 Test hook CK 284 1 BNC output cable CK 310 1 50Ω thorough type load CK 50 1 USB connecting cable AM BM 1 5m 1 High class tool box 1 Instruction manual 1 Warranty card 1 Test report 1 CYBERTEK SHENZHEN ZHIYONG ELECTRONICS CO LTD Addr Room A1702 Building 4 TianAn C...

Reviews: