2.2.2 Landscape Orientation
3
N
OTE
:
Portrait mounting orientation requires 11U (19.2
″
) free rack space.
3
N
OTE
: Follow Section 2.2.1 Rack-Mount Gasket Installation procedure prior to
beginning the steps below.
1.
Align mounting plate rack-mount holes with server rack mounting holes; see Figure 3
for correct mounting orientation.
Ensure gasket faces outward
.
2.
Install the eight 10-32 1/2
″
button head bolts into rack-mounting holes to secure
mounting plate to the server rack.
3
N
OTE
: Steps 3 & 4 require two people.
3.
Align studs with the display mounting holes in mounting plate and install the
C
Y
RAQ
®
until the gasket is flush with rear of enclosure.
Important!
Do not exceed 30 in/lbs when tightening mounting nuts.
4.
From inside rack, a second person must install and tighten the fourteen 10-32
mounting nuts.
Figure 3: Rack-Mount Landscape Installation