background image

 

REPLACING THE BATTERY

only OM1500ATLCD

 

Replacement of batteries located in an 

OPERATOR ACCESS AREA.

 

1.  When replacing batteries, replace with the same number of the following battery: Cyberpower / 

RBP0089for the OM1500ATLCD. 

2. 

CAUTION! 

  Risk of Energy Hazard, 12V, maximum 7.5Ampere-hour battery. Before replacing 

batteries, remove conductive jewelry such as chains, wrist watches, and rings. High energy 
conducted through these materials could cause severe burns. 

3. 

CAUTION!

    Do not dispose of batteries in a fire. The batteries may explode. 

4. 

CAUTION!

    Do not open or mutilate batteries. Released material is harmful to the skin and eyes. 

It may be toxic. 

5. 

CAUTION! 

A battery can present a risk of electrical shock and high short circuit current. The 

following precautions should be observed when working on batteries: 

1) Remove watches rings, or other metal objects. 
2) Use tools with insulated handles. 

CAUTION - RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE 
OF USED BATTERIES ACCORDING TO LOCAL REGULATIONS. 
 
BATTERY REPLACEMENT PROCEDURE 

1. 

Turn off and unplug all connected equipment. 

2. 

Turn the UPS off and unplug it from the AC power source. 

3. 

Turn the UPS on its side. 

4. 

Remove the screws on the bottom of the front panel and lay aside. 

5. 

Remove the front panel of the UPS: pull and lift it. 

6. 

Take out the battery compartment cover. 

7. 

Disconnect the battery wires from the battery. 

8. 

Remove the battery from the compartment.   

9. 

Put the battery back into the compartment.   

10.  Install the replacement battery by connecting the red wire (+) and black wire (-) to the same color 

connectors from the battery pack.   

11.  Replace the battery compartment cover. 
12.  Align the front panel and tighten the retaining screws. 
13.  Recharge the UPS for 8-16 hours to fully charge the battery. 

 

 
REMINDER:  

Batteries are considered HAZARDOUS WASTE and must be disposed of properly.   

Most retailers that sell lead-acid batteries collect used batteries for recycling, as required by local 
regulations.

 

 

TECHNICAL SPECIFICATIONS 

 

Model 

 

OM750ATLCD OM900ATLCD 

OM1500ATLCD 

Capacity  (VA) 

750VA 

900VA 

1500VA 

Input 

 

 

 

 

Voltage Range 

82~148Vac 

Frequency 50/60Hz(Auto 

Sensing) 

Output 

 

 

 

 

On Battery Output 
Voltage 

Simulated Sine Wave at /-10% 

On Battery Output 
Frequency  

50/60 Hz +/-1Hz 

Overload Protection 

Breaker/Internal Current Limiting 

Physical 

 

 

 

 

Outlets-total 6 8 
Outlets-Battery & 
Surge Protected 

3 4 

Outlets-SurgeOnly 
Protected 

3 4 

Dimensions(W XH X 
D)mm 

96 X 138 X 286 

148 X 178 X 298 

Weight (kg) 

4.0 

4.9 

9.3 

Battery 

 

 

 

 

Sealed Maintenance 
Free Lead Acid 
Battery 

RBP0043X 1 

RBP0110X 1 

RBP0089X 2 

Typical Recharge 
Time 

8 Hours 

Warning Diagnostics 

Indicators 

Power On, UPS Status Display, Capacity Display, Digital Value Display 

Audible Alarms 

On Battery, Low Battery, Overload 

Environmental 

 

 

 

 

Operating 
Temperature 

0

C to 40

C  

Operating Relative 
Humidity 

0 to 90% 

Communication 

 

 

 

 

PowerPanel

®

 

Personal Edition 
Software 

Windows 7/ Windows 8/Vista/XP/2000/Server 2003, Linux 

Management 

 

 

 

 

Auto-Charger Yes 
Auto-Restart Yes 
USB Yes 

 

DEFINITIONS FOR ILLUMINATED LCD INDICATORS 

 

 

LCD Indication 

 

 

 

 

Line mode 

Select SW 

Press 

UPS Status Display 

Capacity Display 

Digital Value Display 

 

 

 

 

Load 

Cap. 

Battery 

Cap. 

Input 

Voltage

Output 

Voltage

Run 

Time 

of Load 

of Batt. 

Initial 

V X -- X V X    V       

1st 

V X -- X V X      V     

2nd 

V X -- X V X        V   

3rd 

-- 

V     V 

4th 

-- 

V     

5th(Return)  V X -- X V X    V       

Press >3sec 

(Sound Disable) 

V X V X -- -- -- -- -- -- -- 

Press >3sec 

again 

(Sound Enable) 

V X X X -- -- -- -- -- -- -- 

(Overload)  V X -- V -- -- -- -- -- -- -- 

“V” : Illuminated,    “X” : Not Illuminated,    “--“ : Either 

 

Battery mode 

Select SW 

Press 

UPS Status Display 

Capacity Display 

Digital Value Display 

 

 

 

 

Load 

Cap. 

Battery 

Cap. 

Input 

Voltage

Output 

Voltage

Run 

Time 

of Load 

of Batt. 

Initial 

X V -- X X V    V       

1st 

X V -- X X V      V     

2nd 

X V -- X V X        V   

3rd 

-- 

V     V 

4th 

-- 

V     

5th(Return)  X V -- X X V    V       

Press >3sec 

(Sound Disable) 

X V V X -- -- -- -- -- -- -- 

Press >3sec 

again 

(Sound Enable) 

X V X X -- -- -- -- -- -- -- 

(Overload)  X V -- V -- -- -- -- -- -- -- 

“V” : Illuminated,    “X” : Not Illuminated,    “--“ : Either

 

 

TROUBLE SHOOTING

 

 

Problem 

Possible Cause 

Solution 

The UPS does 
not perform 
expected 
runtime. 

Batteries are not fully charged.

Recharge the battery by leaving the UPS 
plugged in. 

Battery is slightly worn out. 

Contact CyberPower Systems Technical 
Support. 

The UPS will not 
turn on. 
 

The on/off switch is designed 
to prevent damage by rapidly 
turning it off and on. 

Turn the UPS off. Wait 10 seconds and then 
turn the UPS on. 

The unit is not connected to an 
AC outlet. 

The unit must be connected to a 
120V50/60Hz outlet.     

The battery is worn out. 

Contact CyberPower Systems Technical 
Support. 

Mechanical problem. 

Contact CyberPower Systems Technical 
Support.  

Outlets do not 
provide power to 
equipment 

Circuit breaker is tripped due 
to overload 

Turn the UPS off and unplug at least one 
piece connected equipment. Unplug the 
power cord of the UPS then press the circuit 
breaker knob. 

Batteries are discharged 

Allow the unit to recharge for at least 4 
hours. 

Unit has been damaged by a 
surge or spike. 

Contact CyberPower Systems Technical 
Support.  

PowerPanel® 
Personal Edition 
is inactive 

The serial/USB cable is not 
connected. 

Connect the serial/USB cable to the UPS 
unit and an open serial port on the back of 
the computer. You must use the cable that 
came with the unit. 

The unit is not providing 
battery power. 

Shutdown your computer and turn the UPS 
off. Wait 10 seconds and turn the UPS back 
on. This should reset the unit. 

 

For more information, visit 

www.cyberpower.com

 

All rights reserved. Reproduction without permission is prohibited. 

 
 
 
 
 
 

 

Summary of Contents for OM750ATLCD

Page 1: ...láser trituradoras de papel copiadoras calefactores bombas o cualquier otro dispositivo que demande gran consumo de energía en las tomas de batería y picos La demanda de energía de estos equipos puede sobrecargar y dañar la unidad 3 Conecte el UPS en una toma de pared aterrizada de dos polos y 3 cables Asegúrese que elcircuito eléctrico de pared esté protegido por fusible o breaker y que no dé ser...

Page 2: ... 148Vac Frecuencia 50 60Hz Detección automática Salida Voltaje de Salida en Batería Simulación de onda senoidal120Vac 10 Frecuencia de salida en batería 50 60 Hz 1Hz Proteccióncontra sobrecargas Limitando corriente interna Disyuntor Térmico Tomas Tomas totales 6 8 Tomas de batería ysupresión de picos 3 4 Tomasúnicamente de supresión de picos 3 4 Dimensiones AnXAl X F mm 96 X 138 X 286 148 X 178 X ...

Page 3: ... does not exceed the UPS unit s rated capacity If rated unit capacities are exceeded an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip 2 There are many factors that can affect the amount of power that your computer system will require For optimal system performance keep the attached load below 80 of the UPS s rated capacity HARDWARE INSTALLATION GUI...

Page 4: ...8 Hours Warning Diagnostics Indicators Power On UPS Status Display Capacity Display Digital Value Display Audible Alarms On Battery Low Battery Overload Environmental Operating Temperature 0 C to 40 C Operating Relative Humidity 0 to 90 Communication PowerPanel Personal Edition Software Windows 7 Windows 8 Vista XP 2000 Server 2003 Linux Management Auto Charger Yes Auto Restart Yes USB Yes DEFINIT...

Reviews: