OM750ATLCD/OM900ATLCD/OM1500ATLCD 

User’s Manual 

 

K01-C000102-02 

IMPORTANT SAFETY INSTRUCTIONS 

(SAVE THESE INSTRUCTIONS)

 

This manual contains important safety instructions. Please read and follow all instructions carefully 
during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, 
install, or operate your UPS. 
 

CAUTION! 

To prevent the risk of fire or electric shock, install in a temperature and humidity controlled 

indoor area free of conductive contaminants. (See the specifications for the acceptable temperature and 
humidity range.) 

CAUTION! 

To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and avoid 

exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space 
heaters or furnaces. 

CAUTION!

 Do not attach non-computer-related items, such as medical equipment, life-support 

equipment, microwave ovens, or vacuum cleaners to UPS. 

CAUTION!

 Do not plug the UPS input into its own output. 

CAUTION! 

Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any 

other liquid-containing vessels on or near the unit. 

CAUTION!

 In the event of an emergency, press the OFF button and disconnect the power cord from the 

AC power supply to properly disable the UPS. 

CAUTION!

 Do not attach a power strip or surge suppressor to the UPS. 

CAUTION!

 Internal battery voltage is 12Vdc. Sealed, lead-acid, 6-cell battery. 

CAUTION!

 Servicing of batteries should be performed or supervised by personnel knowledgeable of 

batteries and the required precautions. Keep unauthorized personnel away from batteries. 

CAUTION! 

When replacing the batteries, use the same number and type of batteries. 

CAUTION!

 Do not dispose of batteries in a fire. The battery may explode. Do not open or mutilate the 

battery or batteries. Released electrolyte is harmful to the skin and eyes. 

CAUTION! 

Unplug the UPS prior to cleaning and do not use liquid or spray detergent. 

CAUTION! 

A battery can present a risk of electric shock and high short circuit current. The following 

precaution should be observed before replacing batteries: (1) Remove watches, rings, or other metal 
objects.(2) Use tools with insulated handles.(3) Wear rubber gloves and boots.(4) Do not lay tools or 
metal parts on top of batteries. (5) Disconnect charging source prior to connecting or disconnecting 
batteries terminal. 
 

INSTALLING YOUR UPS SYSTEM 

 

UNPACKING 

 
Inspect the UPS upon receipt. The box should contain the following: 
(a)UPS (b) User Manual(c) USB Cable   

*PowerPanel® Personal Edition software is available on our website. Please visit 
www.cyberpower.com and go to the Software Section for free download. 

 

OVERVIEW 

 
TheOM750ATLCD/OM900ATLCD/OM1500ATLCD provides automatic voltage regulation for inconsistent 
utility power, and battery backup during power outages. The OM750ATLCD/OM900ATLCD/ 
OM1500ATLCD ensures consistent power to your computer system and its included software will 
automatically save your open files and shutdown your computer system during a utility power loss. 
 

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 

 
1. 

Insure that the equipment plugged into the battery power-supplied outlets does not exceed the UPS 
unit’s rated capacity. If rated unit capacities are exceeded, an overload condition may occur and 
cause the UPS unit to shut down or the circuit breaker to trip.

 

2. 

There are many factors that can affect the amount of power that your computer system will require.   
For optimal system performance keep the attached load below 80% of the UPS’s rated capacity. 

 

HARDWARE INSTALLATION GUIDE 

 

1. 

Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 
8 hours is recommended to ensure that the battery's maximum charge capacity is achieved. Charge 
loss may occur during shipping and storage. To recharge the battery, plug the UPS into an AC 
outlet. The unit will charge in both the on and off position. 

2. 

With the UPS turned off and unplugged, connect the computer, monitor, and any equipment into the 
battery power supplied outlets. 

DO NOT plug a laser printer, copier, space heater, vacuum, 

paper shredder or other large electrical device into the battery power supplied outlets. The 
power demands of these devices will overload and possibly damage the unit.

 

3. 

Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch 
outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical 
demands (e.g. air conditioner, refrigerator, copier, etc.) Avoid using extension cords. 

4. 

Depress the power switch to turn the UPS on. The power on indicator light will illuminate and the 
UPS will "beep". 

5. 

If an overload is detected, an audible alarm will sound and the UPS will emit one long beep. To 
correct this, turn the UPS off and unplug at least one piece of equipment from the battery power 
supplied outlets. Wait 10 seconds. Make sure the circuit breaker is depressed and then turn the 
UPS on. 

6. 

To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 

7. 

To store your UPS for an extended period, cover it and store with the battery fully charged. 
Recharge the battery every three months to ensure battery life. 
 

 

BASIC OPERATION 

 

FRONT PANEL DESCRIPTION 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1. LCD 

Display 

The LCD will display the UPS status including input voltage, output voltage, runtime, percentage of 
load and battery etc. 

 

2. 

Power On/Off Switch 

Press the power switch to turn the UPS ON or OFF. 

 

3. 

LCD Function Button 

This button is used to select the LCD display contents Including input/output voltage and estimated 
run time, etc. Press this button simultaneously for 3 seconds to disable or enable the alarm system 
while in battery mode. 

 

REAR PANEL DESCRIPTION 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1. USB 

Port

 

This port allows connection and communication from the USB port on the computer to the UPS. 
The UPS communicates its status to the 

PowerPanel

®

 Personal Edition

 software. 

 

2. 

Communication Protection Ports 

Communication protection ports will protect any standard modem, fax, telephone line, or network 
cable. 
 

3. 

TV Coaxial Terminal 

Protects devices such as cable modems, DSS, and cable TV modules. 
 

4. 

Input Circuit Breaker

 

The circuit breaker provides overload protection. 
 

5. 

Input power cord 

Connect to utility power. 

 

6. 

Surge Protected Outlets

 

Provides surge protection for devices that don’t require battery backup.   
 

7. 

Battery Backup & Surge Protected Outlets

 

Provides battery backup and surge protection. They ensure power is provided to connected 
equipment over a period of time during a power failure. 

 
 

 

Summary of Contents for OM750ATLCD

Page 1: ...láser trituradoras de papel copiadoras calefactores bombas o cualquier otro dispositivo que demande gran consumo de energía en las tomas de batería y picos La demanda de energía de estos equipos puede sobrecargar y dañar la unidad 3 Conecte el UPS en una toma de pared aterrizada de dos polos y 3 cables Asegúrese que elcircuito eléctrico de pared esté protegido por fusible o breaker y que no dé ser...

Page 2: ... 148Vac Frecuencia 50 60Hz Detección automática Salida Voltaje de Salida en Batería Simulación de onda senoidal120Vac 10 Frecuencia de salida en batería 50 60 Hz 1Hz Proteccióncontra sobrecargas Limitando corriente interna Disyuntor Térmico Tomas Tomas totales 6 8 Tomas de batería ysupresión de picos 3 4 Tomasúnicamente de supresión de picos 3 4 Dimensiones AnXAl X F mm 96 X 138 X 286 148 X 178 X ...

Page 3: ... does not exceed the UPS unit s rated capacity If rated unit capacities are exceeded an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip 2 There are many factors that can affect the amount of power that your computer system will require For optimal system performance keep the attached load below 80 of the UPS s rated capacity HARDWARE INSTALLATION GUI...

Page 4: ...8 Hours Warning Diagnostics Indicators Power On UPS Status Display Capacity Display Digital Value Display Audible Alarms On Battery Low Battery Overload Environmental Operating Temperature 0 C to 40 C Operating Relative Humidity 0 to 90 Communication PowerPanel Personal Edition Software Windows 7 Windows 8 Vista XP 2000 Server 2003 Linux Management Auto Charger Yes Auto Restart Yes USB Yes DEFINIT...

Reviews: