CPS325SL
Guaranteed Uninterruptible Power System
5
5. Shutdown
Button
: Click the shutdown button to open the
Scheduled Shutdown Window
.
6. Battery
OK
Indicator
: This indicator appears in a green color when AC power is normal and the
unit and software are communicating.
7. AC
Power
Indicator
: This indicator appears in a green color when AC power in normal. When
the power fails, the indicator will change to a red color with an “X” through it.
8. Scheduled
Shutdown:
If there is a shutdown scheduled within seven days, the information will
be displayed here. The user can schedule a shutdown in the
Scheduled Shutdown Window
.
9. Final
Countdown:
When the final countdown timer reaches zero, the software will begin shutting
down the system. This can be adjusted in the
Setup Window
.
POWERPANEL™ SETUP WINDOW
1. Delay Between Warning Mes-
sages:
This setting determines the
delay between the audible alarms.
2. Time Between Power Failure and
Initial Warning:
This setting de-
termines the delay between when
the power fails and the first audible
alarm.
3. Time Between Power Failure and
Shutdown Process:
This user adjustable setting determines how long the UPS will run on bat-
tery before starting to shut down the system. If this is not checked, the unit will run on battery un-
til the low battery condition is met (2 minutes of backup time remaining), and then start the shut-
down process. If the low battery condition is met before this timer reaches zero, the software will
start the shutdown process.
4. UPS is Installed On:
This shows the current COM port that the UPS is using. The port assigned
to the UPS needs to be used exclusively for the PowerPanel™ software.
5. OK
Button:
This button is used to exit the setup window
and save any changes
.
6. Cancel
Button:
This button is used to exit the setup window
without saving any changes
.
7. About
Button:
This button will display information about the software as well as contact informa-
tion.
POWERPANEL™ LOG WINDOW
1. Display
Window:
This area displays
either the
Event Log
or the
Closed Ap-
plication Information
.
2. Event
Log:
Select this option to view
PowerPanel™ events such as program
start, program end, power failure and low
battery.
3. Closed
Application
Information:
Select this option to view the file names of applications that
were saved by PowerPanel™. Please note: If an application has an existing file name, it will be
saved under that file name and not appear in this window.
4. OK
Button:
This button is used to exit the window.
5. Clear
Button:
This button is used to clear the information in the selected log.
POWERPANEL™ SHUTDOWN WINDOW
1. Display
Window:
Any schedule informa-
t i o n w i l l b e d i s p l a y e d h e r e .
2. Special Setting:
This option is used to
schedule a shutdown at a specific date
and time.
3. Weekly Setting:
This option is used to
schedule a shutdown for a specific time
and day of the week.
4. OK
Button:
This button is used to exit