CyberPower CPS325SL Manual Download Page 5

CPS325SL 

Guaranteed Uninterruptible Power System 

 

5. Shutdown 

Button

:  Click the shutdown button to open the 

Scheduled Shutdown Window

6. Battery 

OK 

Indicator

:  This indicator appears in a green color when AC power is normal and the 

unit and software are communicating. 

7. AC 

Power 

Indicator

:  This indicator appears in a green color when AC power in normal.  When 

the power fails, the indicator will change to a red color with an “X” through it. 

8. Scheduled 

Shutdown: 

 

If there is a shutdown scheduled within seven days, the information will 

be displayed here.  The user can schedule a shutdown in the 

Scheduled Shutdown Window

9. Final 

Countdown:

  When the final countdown timer reaches zero, the software will begin shutting 

down the system.  This can be adjusted in the 

Setup Window

POWERPANEL™ SETUP WINDOW 

1. Delay Between Warning Mes-

sages:  

This setting determines the 

delay between the audible alarms. 

2.  Time Between Power Failure and 

Initial Warning:  

This setting de-

termines the delay between when 
the power fails and the first audible 
alarm. 

3.  Time Between Power Failure and 

Shutdown Process:

  This user adjustable setting determines how long the UPS will run on bat-

tery before starting to shut down the system.  If this is not checked, the unit will run on battery un-
til the low battery condition is met (2 minutes of backup time remaining), and then start the shut-
down process.  If the low battery condition is met before this timer reaches zero, the software will 
start the shutdown process. 

4.  UPS is Installed On:

  This shows the current COM port that the UPS is using.  The port assigned 

to the UPS needs to be used exclusively for the PowerPanel™ software. 

5. OK 

Button:

  This button is used to exit the setup window 

and save any changes

6. Cancel 

Button:

  This button is used to exit the setup window 

without saving any changes

7. About 

Button:

  This button will display information about the software as well as contact informa-

tion. 

POWERPANEL™ LOG WINDOW 

1. Display 

Window: 

 

This area displays 

either the 

Event Log

 or the 

Closed Ap-

plication Information

2. Event 

Log: 

 

Select this option to view 

PowerPanel™ events such as program 
start, program end, power failure and low 
battery. 

3. Closed 

Application 

Information:

  Select this option to view the file names of applications that 

were saved by PowerPanel™.  Please note:  If an application has an existing file name, it will be 
saved under that file name and not appear in this window. 

4. OK 

Button:

  This button is used to exit the window. 

5. Clear 

Button:

  This button is used to clear the information in the selected log. 

POWERPANEL™ SHUTDOWN WINDOW 

1. Display 

Window: 

 

Any schedule informa-

t i o n   w i l l   b e   d i s p l a y e d   h e r e . 

2. Special Setting:

  This option is used to 

schedule a shutdown at a specific date 
and time. 

3. Weekly Setting:

  This option is used to 

schedule a shutdown for a specific time 
and day of the week. 

4. OK 

Button:

  This button is used to exit  

 

Summary of Contents for CPS325SL

Page 1: ...al appli cations DO NOT use in any circumstance that would affect operation or safety of any life support equipment or with any medical applications or patient care DO NOT USE WITH OR NEAR AQUARIUMS T...

Page 2: ...omputer system will re quire The total load that you will be placing on the battery powered outlets should not exceed 80 of the unit s capacity Hardware Installation Guide 1 Your new UPS may be used i...

Page 3: ...o the UPS and an open serial port on the back of the com puter Note You must use the serial cable that was supplied with the unit 3 Plug the UPS into an AC outlet turn the UPS on and then start your c...

Page 4: ...greater is designed for use with Windows 95 Windows 98 Windows Me Windows NT and Windows 2000 The latest version can be downloaded from www cyberpowersystems com downloads htm It works in conjunction...

Page 5: ...start the shut down process If the low battery condition is met before this timer reaches zero the software will start the shutdown process 4 UPS is Installed On This shows the current COM port that t...

Page 6: ...service instead of PowerPanel You can run either PowerPanel or the Windows 2000 UPS service but not both To Configure the Windows 2000 UPS Service 1 Click on Start point to Settings then Control Panel...

Page 7: ...rdinances regarding proper disposal of batteries CAUTION Do not open or mutilate the batteries Released electrolyte is harmful to skin and eyes and may be toxic CAUTION A battery can present a high ri...

Page 8: ...will run out of power shortly Off Up Two Beeps or Rapid Beeps System Overload Occurs when connected equip ment exceeds the rating of unit Turn the UPS off unplug at least one piece of equipment wait...

Page 9: ...ast 24 hours Please leave the unit plugged into an AC outlet and don t turn on the power switch The unit will charge in off position The battery is worn out Contact CyberPower Systems about replacemen...

Page 10: ...NSING Size Length x Width x Height 9 7 8 x 6 3 16 x 3 1 8 24 9cm x 12 0cm x 8 0cm Net Weight 7 4 pounds 3 4Kg Typical Battery Recharge Time 8 hours typical from total discharge Typical Battery Life 3...

Page 11: ...Warranty Limited Warranty CyberPower warrants to you the Initial Purchaser that the Product will be free from defects in material and workmanship for three years from the date of original purchase sub...

Page 12: ...urance or other re sources of recovery payment that are available to the Initial Customer for the Connected Equipment and the name of the power utility supplier for the location of the Connected Equip...

Page 13: ...roperly installed and connected This exclusion applies for example to fluctuations in data transmission or reception by CATV or RF transmis sion or fluctuations or by transients in such transmission D...

Reviews: