INSPECTION 

The box should contain the following: 
(1) PowerPanel™ software (floppy disk); (1) serial interface cable (DB-9);  
(1) telephone communication cable; (1) user manual; (1) warranty registration card; 
(1) UPS unit. 

 

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 

1.  Make sure that the total Volt-Amp (VA) requirements of your computer, monitor and peripheral 

equipment does not exceed 1200

 

VA. 

2.  Insure that the equipment plugged into the three battery power-supplied outlets does not exceed 

the UPS unit’s rated capacity (325VA/185W for CPS325SL).  If rated unit capacities are ex-
ceeded, an overload condition may occur and cause the UPS unit to shut down and the circuit 
breaker to trip.   

3.  If the power requirements of your equipment are listed in units other than Volt-Amps (VA), convert 

Watts (W) or Amps (A) into VA by doing the calculations below.  Note:  The below equation only 
calculates the maximum amount of VA that the equipment can use, not what is typically used by 
the equipment at any one time.  Users should expect usage requirements to be approximately 
60% of below value to estimate power requirements: 
           Watts (W) x 1.82 =            VA or            Amps (A) x 120 =            VA 
Add the totals up for all pieces of equipment and multiply this total by .6 to calculate actual re-
quirements. 
There are many factors that can effect the amount of power that your computer system will re-
quire.  The total load that you will be placing on the battery-powered outlets should not exceed 
80% of the unit’s capacity.

   

 

Hardware Installation Guide 

1.  Your new UPS may be used immediately upon 

receipt.  However, 

recharging the battery for at 

least four hours

 is recommended to insure that 

the battery’s maximum charge capacity is 
achieved.  Charge loss may occur during ship-
ping and storage.  To recharge the battery, sim-
ply leave the unit plugged into an AC outlet and 
turn on the power switch. 

2.  If you wish to use the software, connect the en-

closed serial interface cable to the serial port on the 
UPS and an open serial port on the computer.  If 
you are not going to use the software, you do not 
need to connect the cable. 

3. 

With the UPS unit off and unplugged, connect your 
computer, monitor, and any externally powered 
data storage device (Zip drive, Jazz drive, Tape drive, etc…) into the 
battery power supplied outlets.  Plug your peripheral equipment 
(printer, scanner, speakers) into the full-time surge protection out-
lets.  

DO NOT plug a laser printer, copier, space heater, vacuum 

or other large electrical device into the UPS.  The power de-
mands of these devices will overload and possibly damage the 
unit. 

4.  To protect a fax, phone or modem, connect a telephone cable from 

the wall jack outlet to the in jack of the UPS.  Connect a telephone 
cable from the out jack with the CPU icon to the modem port on your computer. The out jack with 
the telephone icon can be used to protect a telephone or fax machine. 

 

Summary of Contents for CPS325SL

Page 1: ...al appli cations DO NOT use in any circumstance that would affect operation or safety of any life support equipment or with any medical applications or patient care DO NOT USE WITH OR NEAR AQUARIUMS T...

Page 2: ...omputer system will re quire The total load that you will be placing on the battery powered outlets should not exceed 80 of the unit s capacity Hardware Installation Guide 1 Your new UPS may be used i...

Page 3: ...o the UPS and an open serial port on the back of the com puter Note You must use the serial cable that was supplied with the unit 3 Plug the UPS into an AC outlet turn the UPS on and then start your c...

Page 4: ...greater is designed for use with Windows 95 Windows 98 Windows Me Windows NT and Windows 2000 The latest version can be downloaded from www cyberpowersystems com downloads htm It works in conjunction...

Page 5: ...start the shut down process If the low battery condition is met before this timer reaches zero the software will start the shutdown process 4 UPS is Installed On This shows the current COM port that t...

Page 6: ...service instead of PowerPanel You can run either PowerPanel or the Windows 2000 UPS service but not both To Configure the Windows 2000 UPS Service 1 Click on Start point to Settings then Control Panel...

Page 7: ...rdinances regarding proper disposal of batteries CAUTION Do not open or mutilate the batteries Released electrolyte is harmful to skin and eyes and may be toxic CAUTION A battery can present a high ri...

Page 8: ...will run out of power shortly Off Up Two Beeps or Rapid Beeps System Overload Occurs when connected equip ment exceeds the rating of unit Turn the UPS off unplug at least one piece of equipment wait...

Page 9: ...ast 24 hours Please leave the unit plugged into an AC outlet and don t turn on the power switch The unit will charge in off position The battery is worn out Contact CyberPower Systems about replacemen...

Page 10: ...NSING Size Length x Width x Height 9 7 8 x 6 3 16 x 3 1 8 24 9cm x 12 0cm x 8 0cm Net Weight 7 4 pounds 3 4Kg Typical Battery Recharge Time 8 hours typical from total discharge Typical Battery Life 3...

Page 11: ...Warranty Limited Warranty CyberPower warrants to you the Initial Purchaser that the Product will be free from defects in material and workmanship for three years from the date of original purchase sub...

Page 12: ...urance or other re sources of recovery payment that are available to the Initial Customer for the Connected Equipment and the name of the power utility supplier for the location of the Connected Equip...

Page 13: ...roperly installed and connected This exclusion applies for example to fluctuations in data transmission or reception by CATV or RF transmis sion or fluctuations or by transients in such transmission D...

Reviews: