When your computer restarts, the Power-
Panel™ software will appear on your screen 
for a few seconds, and then minimize.  It will 
appear as a blue and white battery icon located 
in the system tray, near the clock. 

FOR WINDOWS 2000 

1. Click 

on 

Start

, point to 

Settings

, and then click 

Control Panel

2. Double-click 

on 

Power Options

3. On 

the 

UPS Tab

, click 

Select

4. In 

the 

UPS Selection Dialog Box

, under 

Manufacturers

, click 

None

5.  Exit to the desktop. 
6. Shutdown 

the 

computer. 

7.  Turn the UPS off and unplug it. 
8.  Connect the serial interface cable to the UPS and an open serial port on the back of your com-

puter.  (Note:  You must use the cable that was supplied with the unit). 

9.  Plug the UPS into an AC outlet, turn the UPS on and then start your computer. 
10. Click on 

Start

, point to 

Settings

, and then click 

Control Panel

11. Double-click 

Add/Remove Programs

12. Insert the software disk into the floppy drive. 
13. Click 

Install

14. Follow the on-screen instructions. 
15. Once the software is installed, remove the floppy disk and restart your computer. 
When your computer restarts, the Power-
Panel™ software will appear on your screen for 
a few seconds, and then minimize.  It will ap-
pear as a blue and white battery icon located in 
the system tray, near the clock. 

 

POWERPANEL™ SOFTWARE USER MANUAL 

OVERVIEW 

PowerPanel™ version 2.03 or greater is designed for use with Windows 95, Windows 98, Windows 
Me, Windows NT and Windows 2000.  The latest version can be downloaded from 

www.cyberpowersystems.com/downloads.htm

.  It works in conjunction with the UPS to provide full 

protection of valuable computer systems, applications and data.  In the event of a power failure, 
PowerPanel™ automatically saves and closes open files under auto-assigned file names or existing 
files names after a software controlled delay.  The computer and UPS are automatically shutdown to 
conserve battery power.  Files with auto-assigned names will be saved under 

C:\PCTemp

, where 

C

 

is the name of your main hard drive.  Files that have previously been saved will be saved in their 
original location. 
PowerPanel™ is equipped with a 

Scheduled Shutdown

 feature which can automatically save and 

close open files and then shutdown the computer and UPS at a user specified date and time.  Use of 
this feature is optional and is not required for the power failure shutdown to occur. 
The use of the PowerPanel™ software is optional.  The UPS unit will provide full surge suppression 
and battery backup without the software.  You must use the software if you wish to have the auto-
matic shutdown feature. 

POWERPANEL™ MAIN WINDOW DESCIPTION 

1. Minimize Button:  

This button is 

used to minimize the software. 

2. Power Button:

  Clicking on the 

power button will stop the soft-
ware. 

3. Setup 

Button:

  Click the setup 

button to open the 

Setup Win-

dow

4. Log 

Button

:  Click on the log button to open the 

Log Window

 

Summary of Contents for CPS325SL

Page 1: ...al appli cations DO NOT use in any circumstance that would affect operation or safety of any life support equipment or with any medical applications or patient care DO NOT USE WITH OR NEAR AQUARIUMS T...

Page 2: ...omputer system will re quire The total load that you will be placing on the battery powered outlets should not exceed 80 of the unit s capacity Hardware Installation Guide 1 Your new UPS may be used i...

Page 3: ...o the UPS and an open serial port on the back of the com puter Note You must use the serial cable that was supplied with the unit 3 Plug the UPS into an AC outlet turn the UPS on and then start your c...

Page 4: ...greater is designed for use with Windows 95 Windows 98 Windows Me Windows NT and Windows 2000 The latest version can be downloaded from www cyberpowersystems com downloads htm It works in conjunction...

Page 5: ...start the shut down process If the low battery condition is met before this timer reaches zero the software will start the shutdown process 4 UPS is Installed On This shows the current COM port that t...

Page 6: ...service instead of PowerPanel You can run either PowerPanel or the Windows 2000 UPS service but not both To Configure the Windows 2000 UPS Service 1 Click on Start point to Settings then Control Panel...

Page 7: ...rdinances regarding proper disposal of batteries CAUTION Do not open or mutilate the batteries Released electrolyte is harmful to skin and eyes and may be toxic CAUTION A battery can present a high ri...

Page 8: ...will run out of power shortly Off Up Two Beeps or Rapid Beeps System Overload Occurs when connected equip ment exceeds the rating of unit Turn the UPS off unplug at least one piece of equipment wait...

Page 9: ...ast 24 hours Please leave the unit plugged into an AC outlet and don t turn on the power switch The unit will charge in off position The battery is worn out Contact CyberPower Systems about replacemen...

Page 10: ...NSING Size Length x Width x Height 9 7 8 x 6 3 16 x 3 1 8 24 9cm x 12 0cm x 8 0cm Net Weight 7 4 pounds 3 4Kg Typical Battery Recharge Time 8 hours typical from total discharge Typical Battery Life 3...

Page 11: ...Warranty Limited Warranty CyberPower warrants to you the Initial Purchaser that the Product will be free from defects in material and workmanship for three years from the date of original purchase sub...

Page 12: ...urance or other re sources of recovery payment that are available to the Initial Customer for the Connected Equipment and the name of the power utility supplier for the location of the Connected Equip...

Page 13: ...roperly installed and connected This exclusion applies for example to fluctuations in data transmission or reception by CATV or RF transmis sion or fluctuations or by transients in such transmission D...

Reviews: