Ethernet Line Protection ITU-T G.8031, PBB-TE Layer Protection
Switch times < 50 ms
•
Ethernet Ring Protection ITU-T G.8032, PBB-TE Layer Protection
Switch times < 50 ms with a maximum of 32 ERP nodes
•
Client (UNI) protection
Link Aggregation (802.1AX)
Rapid Spanning Tree (802.1w)
•
OAM
Link OAM 802.3ah and OTN
Service OAM 802.1ag
o
UP and Down MEPs
•
QoS
Ingress per service policing
o
Two Rate Three Color Marker
o
Metering granularity from 1 Mbps to 10 Gbps in 64 Kbps increments
o
Ethernet P-bit priority to CoS mapping
o
DSCP to CoS mapping
•
Egress shaping
8 class of service queues per port
•
Egress scheduling
Strict Priority
Weighted Round Robin (WRR)
Deficit Weighted Round Robin (DWRR)
•
Synchronous Ethernet (SyncE)
2.4.4 PME-412 Capacity
•
MAC Addresses: 32,000
•
VLANs (with independent VLAN learning): 4,096
Note:
The VLAN range is 0 to 4095. VLAN 0 is priority-tagged. Provisionable VLAN range is 1 to
4094. VLAN 4095 is reserved by the system.
•
VLAN translation (ingress and egress): 4,000
•
Unique services (E-Line or E-LAN) no policing: 2,000
•
Unique services (E-Line or E-LAN) with policing: 1,000
•
Traffic Engineering Service Instances (TESIs): 512
•
Protected TESI groups per card pair: 256
•
Ethernet Ring Protection Groups per card pair: 256
•
Maintenance association End Points (MEPs): 512
•
Link Aggregation Groups: 16
•
Ports in a Link Aggregation Group: 8
•
Flow Points: 2,048