The number of hops supported in the OOO configuration varies based on the maximum length of
each hop as shown in the table below:
Loss per Fiber Span
Maximum Number
of Fiber Hops
18 dB
10+
20 dB
10
22 dB
8
24 dB
6
26 dB
5
28 dB
3
WSS-402 Block Diagram
Figure 66: WSS-402 DWDM Diagram