G.975.1 Appendix 7 Universal Forward Error Correction (UFEC)
•
Physical: Front access, fixed wavelength XFP optics
•
Transponder and regeneration functions in conjunction with Z-Series LAD modules
2.3.3 Management
•
Standard SONET/SDH OTN General Communication Channel (GCC0)
•
A – Z circuit provisioning using Planet Operate
•
SNMP v2
•
CLI
•
TL1
2.3.4 Physical
•
Module dimensions:
Depth: 11.6" / 295 mm
Width: 1.2" / 30.5 mm
Height: 13.8" / 350 mm
•
Weight: 4 lbs / 1.8 kg
2.3.5 Power
•
Dual -48V DC power feeds to module slots
•
Power consumption: 55 watts typical, 65 watts maximum
2.3.6 Environmental
•
+32°F to +122°F / 0°C to +50°C operating temperature
•
5% to 85% operating relative humidity (non-condensing)
•
13,000 feet (4,000 m) altitude
2.3.7 Compliance / Safety
•
NEBS 3 Certified (GR-63 CORE, GR-1089)
•
UL/CSA Listed
•
UE/CE-Marked: EN 60950, EN 55022, EN 6 1000, ETSI EN 300 386 V.1.3.3
•
CB Scheme Certified 60950
•
FCC, Subpart B, Part 15, Class A
•
RoHS compliant