Client/ Company _______________________________
Contact Person
_______________________________
Installation date
_____________
Pipe diameter
_____________
Pipe material
_____________
1. Is the installation place chosen with respect to these factors?
Time Factor / Heat Factor / Distance Factor
OK
2. Are there unusual high levels of certain substances in the water? If yes, have they be taken care of?
Fe: The iron concentration in the water should not exceed 1 mg/l (1 ppm)
Mn: The manganese level should not exceed 0.1 mg/l (0.1 ppm)
OK
3. Have the location of filters and pumps been taken into consideration?
As a general rule it is better to install Vulcan after a pump and after a filter, if the setting in your installation area allows it.
Filters:
Crude filters (> 50 µ) do not remove the mono-crystals and can be ignored. For more sensitive filters (< 50 µ)
it is recommended to install Vulcan after the filter.
Pumps:
If possible, we advise installing Vulcan after any pumps.
OK
4. Have you checked for strong electricity, magnetic fields or electro-motors?
Please make sure that there are no strong electric lines running close to the installation area.
High voltage electric lines or strong magnetic fields may interfere with the Vulcan impulse-field.
OK
5. Are paint or cover materials on the pipe taken care of?
• Thin coatings such as pipe protection (e.g. corrosion protection paint) are suitable to place the impulse-bands
directly on top.
• Insulation material or other thicker protective layers should be dismantled and can be re-installed over the
impulse bands after installation.
OK
6. Is the pipe surface temperature suitable?
The pipe’s outside temperature should not exceed 65°C (~ 149° F). Above this may harm the isolation of the copper
impulse bands.
OK