8
GB
room the scale powder is left behind. There
are no more hard deposits and residues can be
removed easily with a damp cloth.
Harsh
cleaning detergents are no longer needed.
Because calmat
®
is installed on the outside of the
pipe and there is no direct contact with the water,
the water is not chemically altered.
Important
minerals and natural elements remain for the
human organism. Food and drinks keep their
natural taste.
General advice
calmat
®
can be used with any pipe material:
Metal pipes: iron, copper, stainless steel, lead,…
Synthetic/plastic pipes: PVC, PE, PP, compound
pipes,…
- calmat
®
is applicable to pipe cross sections of
max. 3 inch (~.75 mm)
calmat
®
works most effectively at temperatures
up to 97° C (203° F) surface-contact temperature
- calmat
®
is absolutely independent from the
velocity of the water
- calmat
®
functions reliable and has no maintenance
costs
Technical Information
Rated voltage:
24
V
~
Rated input:
1.5 W
Voltage supply:
100-240 V~ (50/60 Hz)
Impulse cables:
4 x 5 m
Output:
4 x capacitive
Dimensions (H/W/D):
180 x 150 x 50 mm
Max. pipe-Ø:
3“ (~ 75 mm)
Safety instructions
Attention:
Please read the instruction manual before
installing and starting up the system!
To avoid causing damage, please follow these safety
instructions:
- Connect calmat
®
only to a correct and firmly
installed earthed safety socket (100–240 V
~,
50/60 Hz).
- Do not disconnect from power by pulling the wire.
Always disconnect pulling the plug.
- Do not open the electronic unit.
- The exterior temperature where the unit is
installed should be between -10° C until max. +55° C.
- The power plug should be kept away from water
drops and water spray.
- Please clean the unit with a damp cloth only
(no detergents).
- Protect calmat
®
from direct humidity, water and
direct solar radiation.
Installation instructions
The electronic water treatment system calmat
®
prevents scale and rust deposits in pipes and de-
vices. The unit is installed on the main water sup-
ply (e.g. close to the water meter) according to the
following instructions:
- The electronic control unit can be attached
directly on to the pipe. This can be done either
horizontally and vertically. It may also be placed
on the wall.
- Wind the impulse cable tightly and firmly without
gaps around the pipe.
- The impulse cable can also be wound on thicker
connecting pieces (e. g. pipe collars, pipe reducers,
compression couplings etc.).
- Before the installation, casing or insulating material
on the pipe must be removed. Thin coats of paint
can be left.
Installation
1)
Place calmat
®
on the pipe. Install calmat
®
on the
main water pipe and fix the electronic unit with the
cable ties.