background image

 

Page 58 of 58 

 
 
 
 

 

 

ONLY USE GENUINE REPLACEMENT PARTS. 

 

Spirit Fires Ltd, 

4 Beaumont Square 

Aycliffe Industrial Park, 

Newton Aycliffe 

County Durham, 

DL5 6XN 

T – 01325 327 221 

F – 01325 327 292 

www.spiritfires.co.uk 

[email protected] 

 

 

 

This revision is dated on the 20-10-2015.  

 

The information supplied in this manual is correct at 

the time of publication. There may be changes made 

in future as we improve our products.  

 

If there are any queries about this appliance please 

call our technical department on 01325-327221. 

 

You can also find many technical sheets and guides 

on our website.  

 

Summary of Contents for FR-850-V

Page 1: ...take the time to read through these instructions and follow them step by step Please quote this serial number when calling to discuss installation and spare part requests The Warranty is valid for 1 Y...

Page 2: ...ng the Appliance Page 26 Fitting the Logs Page 29 Fitting the Pebbles Page 30 Final Safety Check List Page 31 Commissioning Sheet Page 32 Fire Guards Hearths Page 33 Technical Fault Diagnosis Troubles...

Page 3: ...rement of 178mm diameter or Class 1 chimney at 2m in length This version needs room ventilation with a 100cm2 air vent to the outside air RIBBON FR 850 NV Natural Gas Only This version has a minimum f...

Page 4: ...TESC Setup Code 228407 Remote Transmitter RF868D Countries of Destination The FR850 is CE approved for installation in the following European Countries with I2H Gas 20mBar or I3P Gas 37mBar AT BG CH C...

Page 5: ...n which it is installed Fascia Trim The RIBBON FR850V RIBBON FR850NV is supplied with a stone fascia This must be used when the fire is installed Only a stone fascia supplied by Spirit Fires must be u...

Page 6: ...R 850 V and FR 850 NV Check the delivery paperwork and Data Plate inside the fire to confirm which version was purchased by the customer The installation should only be carried out by a GAS SAFE regis...

Page 7: ...Page 7 of 58 Construction Dimensions The Spigot on the gather depends on which version was ordered by the customer Check the data plate and the description on page 3...

Page 8: ...ure these are correct for the property supply This Fire has a battery remote control system and requires only the connection of an 8mm gas supply The remote is operated by a radio frequency remote sys...

Page 9: ...e performance The batteries will last a minimum of 12 months or longer however it is advised to ask you gas installer to replace the batteries on each 12 month service The handset will switch the fire...

Page 10: ...the fire is installed a flue test in accordance with National Regulations should be carried out Any flue damper plate or flue restrictor must be removed or fixed permanently in the fully open positio...

Page 11: ...vacuation of the combustion products is interrupted If the fire shuts itself off do not use the fire and have the flue and fire checked by a suitably qualified person FR 850 V This version of the gas...

Page 12: ...Check the technical section on page 4 Has it been tested for leaks 4 Burner Ventilation This is provided by a slot hidden behind the stone trim Do not block the slot See following Section for details...

Page 13: ...so that it allows air to pass between it and the wall into the burner slot See Image Below The correct fitting of the fire enclosure shows the enclosure positioned to the final flush finish of the wal...

Page 14: ...ortant that the gas supply is disconnected before any old existing surround and hearth is removed Measuring from the floor surface the intended location of the base of the enclosure unit is marked ont...

Page 15: ...the fireplace opening required to install the fireplace unit The gather can be installed by first inserting this into the fireplace opening The fire body is then inserted into the opening and the gat...

Page 16: ...e Fireplace into the Opening Once the fireplace opening has been created the appliance can be lifted into the opening Feed the gas pipe through the chosen hole into the lower burner area ready for con...

Page 17: ...clearance of 10mm on each side and 10mm at the top This allows minor adjustment This void should be sealed with a suitable fire retardant material to seal the enclosure to the opening Once installed...

Page 18: ...sealed to ensure all flue gases enter the chimney and cannot leak back in to the room Once the fire is fixed in place the fire can be finished with plasterboard The gather has a spigot to allow conne...

Page 19: ...tion from the room and this is provided by a slot behind the fascia To achieve the correct ventilation the enclosure must protrude into the room 20mm from the finished wall See following images If the...

Page 20: ...Page 20 of 58 The image above shows the fire correctly positioned with the enclosure 20mm forward of the finished wall When installed correctly the fire will look like the below image...

Page 21: ...RIBBON Using any other fascia will make the render the fireplace dangerous and eliminate any warranty Adding the fascia is a two man job The stone fascia is very heavy Remove the wall bracket from th...

Page 22: ...Lift the stone on to the wall bracket and secure by replacing the screws around the perimeter When installed correctly air can flow below the fascia into the burner tray see image below The gas can n...

Page 23: ...appliance Remove the heat shield to gain access to the remote control unit so that the power switch put in the on position Once the heat shield is removed the remote control is visible Remove the shi...

Page 24: ...n the open position to allow gas to flow Remove the screw from the test point within the appliance and connect a manometer With the appliance off check for gas soundness in the supply circuit If there...

Page 25: ...e gauge replace the pressure test point sealing screw and test the appliance for gas soundness Refit the front shelf Refit the Vanity Shelf The vanity shelf is replaced by positioning it correctly whe...

Page 26: ...R850 Log Layout 14 Piece Log Set Fit logs numbered 4 3 Fit logs numbered 9 13 Add the Wool to the burner Add the Wool on top of cut out Do not put wool near the pilot assembly It should be in the cent...

Page 27: ...Page 27 of 58 Add logs numbered 14 17 Add logs numbered 5 8 Add logs numbered 15 11...

Page 28: ...Page 28 of 58 Add logs numbered 16 6 Add logs numbered 10 12 Final layout...

Page 29: ...k 11 pebbles along the front The pebbles must not touch the burner and are positioned on the vanity cover See images below Add the Wool between the pebbles and along the burner bar Do not place any wo...

Page 30: ...card is to be completed by the registered engineer who has commissioned the appliance This is to validate the warranty The card must then be given to the customer for postage back to the factory FINAL...

Page 31: ...essure test appliance off mBar 3 Appliance working pressure on High Setting with all other gas appliances in the house operating on full mBar 4 Appliance working pressure on High Setting with all othe...

Page 32: ...of young children the elderly and infirm The installer is to advise the user not to stand too close to the appliance for prolonged periods of time and warn that loose clothing is particularly at risk...

Page 33: ...edure is not followed and the fire is left to run with the wrong gas pressure the fire will 1 Fail to light 2 Light for a few seconds 3 Shut down unexpectedly 4 Have a low flame 5 Have a yellow flame...

Page 34: ...spark Check the spark is in the right area Check that the ignition lead is connected Check the pilot gas slot is clear Pilot lights but does not light main burner Check the pilot flame is heating the...

Page 35: ...re The gap between the pilot electrode and the pilot should be 3 5 4 5mm and normally adjustment is not necessary the electrode is very brittle The spark should jump across the gap between the electro...

Page 36: ...ng heat damage is not covered by the warranty Remote Control Components The remote control used on this fire has only a small number of components to function a A black remote box gas control valve b...

Page 37: ...ration is as per the manufacturer s instructions That the gas fire burner unit correctly cross lights within 10 seconds A pressure drop test to verify that there are no gas leaks That the electronic i...

Page 38: ...s on this fire Servicing Procedure Turn off the gas fire and allow time for it to cool Remove the vanity cover as shown on page 22 Turn off the gas supply at the isolation tap within the fire INJECTOR...

Page 39: ...alling to order spare parts you will be requested to provide both the serial number of the fire and gas safe registration number of the person who will carry out the repairs The serial number is shown...

Page 40: ...Page 40 of 58...

Page 41: ...en calling to discuss installation and spare part requests The Warranty is valid for 1 Year from date of delivery To register the appliance complete the warranty card supplied and return to Spirit Fir...

Page 42: ...al Information Page 44 Start Shutdown Instructions Page 53 Using the Manual Switch Panel Page 54 Replacing the Batteries Page 55 Cleaning Instructions Page 56 Fire Guards and Hearths Page 57 Warranty...

Page 43: ...ite normal and any odours should disperse within a few hours of operation Do not use the fire when decorating or burning scented candles This will cause additional smells and staining on walls For som...

Page 44: ...t is more likely the handset is not being pressed correctly If the main burner or pilot light is extinguished during lighting do not attempt to re light the pilot within three minutes Quick Start User...

Page 45: ...e unlock light will happen upon touching When the word pilot appears at the bottom left hand corner of the display immediately release the power button A second flash of the unlock light and a longer...

Page 46: ...fit a new set of alkaline batteries like Duracell o c that the small isolation switch on the gas control in the top left corner is in the ON position I and not the OFF position O Grasp the handset in...

Page 47: ...can be seen on YouTube use your internet browser to visit YouTube page and within YouTube search for TESC GAS CONTROL Setting Up The Handset The handset comes paired to the black box so does not need...

Page 48: ...gate through the menu set moves to the next parameter and Mode move back to the previous parameter and change the display parameter Setting the display for 12 or 24 Hour display The H indicates that i...

Page 49: ...Fire Control Advanced settings Menu In the event that you may want to change the other preset settings of the control features Do not do a long press and hold above but a normal short press and relea...

Page 50: ...his happens Pairing the Handset WARNING There should be no reason to do this with a new or working fire as the pairing has been done at the factory This is only to be used in the event of fitting a ne...

Page 51: ...the handset This can only be done after the handset has been made free to pair as shown in step 1 above Ensure all the batteries are fitted correctly and with the power isolator slide switch on the TE...

Page 52: ...nlock as described previously and press the mode button as many times as necessary until the word MAN and the Zzz symbols are flashing at the top of the display Press and release the set button and th...

Page 53: ...o the actual temperature displayed on the handset i e the room ambient temperature around the handset The handset will then adjust the fire flame up and down depending on the required temperature If t...

Page 54: ...e batteries involves removal of the vanity cover and heat shields It is strongly advised to leave this task to a gas safe engineer to perform The best time to change the batteries is during the annual...

Page 55: ...te isolator switch to the left away from the On position symbol 0 Don t forget to switch it back on in the winter Cleaning Instructions Before cleaning the appliance turn off the gas fire and allow it...

Page 56: ...urner unit DO NOT USE THE APPLIANCE contact your installer to ensure the gas fire is still safe and functions correctly Warning Fire Guards Hearths This appliance is not fitted with an integral guard...

Page 57: ...full details of the GAS SAFE engineer who installed the appliance We may also request a copy of the installation receipt Failure to supply details of the Registered Engineer who installed the applian...

Page 58: ...ritfires co uk sales spiritfires co uk This revision is dated on the 20 10 2015 The information supplied in this manual is correct at the time of publication There may be changes made in future as we...

Reviews: