2.4.1 Connection Printer-PC
The following scheme, represent the connection cable con
fi
guration between Molex connector 51021 series
15-pin (female) and a 25-pin connector (female). This cable can be use as wiring between the printer board
and a 25-pin connector (male).
PC
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
21
23
24
25
Printer
5
4
3
2
1
6
7
9
8
10
11
12
13
14
15
JP5
(2)
JP6
(2)
AD0
AD0
STROBE
AD1
AD1
AD2
AD2
AD3
AD3
AD4
AD4
AD5
AD5
AD6
AD6
AD7
AD7
BUSY
ACK
ERROR
BUSY
PAPER END
PAPER END
ACK or FEED
(1)
GND or LED
ERROR
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
STROBE
1
2
NOTE
(1)
Signal not available with Centronics interface.
(2)
For JP5 and JP6 settings see paragraph 1.5.3.
(Fig.2.9)
2. INTERFACES
2-10 PLUS II
User Manual
Summary of Contents for PLUS II
Page 1: ...OEM USER MANUAL PLUS II PLUS II Command Reference DOMC 0009e ...
Page 5: ...1 4 5 PLUS II USB NOTE 1 RESERVED interface only for service use Fig 7 User Manual PLUS II ...
Page 14: ...Blank page INTRODUCTION 6 PLUS II User Manual ...
Page 29: ...2 3 4 Fig 1 20 Fig 1 19 Fig 1 18 1 INSTALLATION AND USE User Manual PLUS II 1 15 ...
Page 32: ...Blank page 1 INSTALLATION AND USE 1 18 PLUS II User Manual ...
Page 50: ...Blank page 3 TECHNICAL SPECIFICATIONS 3 6 PLUS II User Manual ...
Page 63: ......