1.3.2 Setting serial interface
See paragraph 1.2.2.
1.3.3 Power-On confi guration
The JP8 jumper on controller board (see Fig.1.6) manages the power-on setting function as indicated:
J8
CLOSED
Auto Power-On enabled
OPEN
Auto Power-On disabled
If JP8 is closed:
•
The printer switches on when powered up, and it switches off when power is off (default
condition). In this condition the ESC ‘0’ command has not effects.
If JP8 is open:
•
When the printer is powered up the low-consumption mode is activated. An impulse of at
least 500 m/sec on pin 6 of the serial RS232 connector must be given to switch on the printer (see par.
2.2.1 and table 2.2). Use ESC “0” command to switch off the printer and bring it back to low-consumption
mode.
Refer to Fig. 1.6 for the JP8 jumper position.
JP8
JP5
JP6
JP7
JP4
RS232
TTL
JUMPER
SELECTION
POWER-ON
CLOSE=AUTO
OPEN=EXTERNAL
JUMPERS
SELECTION
INTERFACE
JP8
JUMPER
SELECTION
POWER-ON
CLOSE=AUTO
OPEN=EXTERNAL
JP8
JUMPER
SELECTION
POWER-ON
CLOSE=AUTO
OPEN=EXTERNAL
(Fig.1.6)
1. INSTALLATION AND USE
1-6 PLUS II
User Manual
Summary of Contents for PLUS II
Page 1: ...OEM USER MANUAL PLUS II PLUS II Command Reference DOMC 0009e ...
Page 5: ...1 4 5 PLUS II USB NOTE 1 RESERVED interface only for service use Fig 7 User Manual PLUS II ...
Page 14: ...Blank page INTRODUCTION 6 PLUS II User Manual ...
Page 29: ...2 3 4 Fig 1 20 Fig 1 19 Fig 1 18 1 INSTALLATION AND USE User Manual PLUS II 1 15 ...
Page 32: ...Blank page 1 INSTALLATION AND USE 1 18 PLUS II User Manual ...
Page 50: ...Blank page 3 TECHNICAL SPECIFICATIONS 3 6 PLUS II User Manual ...
Page 63: ......