1.8 CONFIGURATION
PLUS II permits the con
fi
guration of default parameters.
The con
fi
gurable parameters for PLUS II-S, PLUS II-S-0004 and PLUS II-T models, are:
Baud Rate :
38400, 19200
D
, 9600, 4800, 2400,1200, 600.
Data Length :
7, 8
D
bits/chr.
Parity :
None
D
, Even, Odd.
Handshaking :
XON/XOFF
D
, or Hardware.
Autofeed:
CR disabled
D
, CR enabled.
Columns:
24 col.
D
, 40 col., 42 col.
Print Mode:
Normal
D
, Reverse.
Char Mode:
Normal
D
, Double width (2 x Width), Double height (2 x Height), Expanded.
Print Density:
-2, -1, 0
D
, +1, +2.
The con
fi
gurable parameters PLUS II-C, PLUS II-C-0004 and PLUS II-P models, are:
Interface:
Centronics, TTL.
Autofeed:
CR disabled
D
, CR enabled.
Columns:
24 col.D, 40 col., 42 col.
Print Mode:
Normal
D
, Reverse.
Char Mode:
Normal
D
, Double width (2 x Width), Double height (2 x Height), Expanded.
Print Density:
-2, -1, 0
D
, +1, +2.
The con
fi
gurable parameters for PLUS II-USB model, are:
Emulation :
PLUS II
D
, ESC/POS.
Baud Rate :
38400, 19200
D
, 9600, 4800, 2400,1200, 600.
Data Length :
7, 8
D
bits/chr.
Parity :
None
D
, Even, Odd.
Handshaking :
XON/XOFF
D
, or Hardware.
Autofeed:
CR disabled
D
, CR enabled.
Print Mode:
Normal
D
, Reverse.
Char / inch :
A=17 B=22 cpi
D
, A=13 B=17 cpi.
Notch Alignment :
Disabled
D
, Enabled.
Notch Distance [mm x 10]
•
(1)
:
0
D
, 1, 2, 3, 4, 5, 6, 7, 8, 9.
Notch Distance [mm x 1]
•
(1)
:
0
D
, 1, 2, 3, 4, 5, 6, 7, 8, 9.
Notch Distance [mm x .1]
•
(1)
:
0
D
, 1, 2, 3, 4, 5, 6, 7, 8, 9.
Print Density:
-50%, -37%, -25%, -12%, 0
D
, +12%, +25%, +37%, +50%, linerless.
Note:
The parameters marked with the symbol
D
are the default values.
Note
(1)
:
If the “Notch Alignment” parameter is set to “Disabled” this parameter doesn’t appear in the
“Printer Setup” report. The “Notch distance” parameter represents the distance in mm from the
upper margin of the ticket to the black mark on the ticket. For example, to set notch distance to
15mm, modify the following parameters in order to obtain the desired values as indicated: Notch
Distance [mm x 10]=1; Notch Distance [mm x 1]=5; Notch Distance [mm x .1]=0.
The settings made are stored in nonvolatile memory and are loaded automatically.
During power-up, if the FEED key is held down, the printer enters the autotest routine and prints out the setup
report. The printer will remain in standby in Hexadecimal dump mode (see par. 1.9) until another key is pressed
or characters are received through the printer communication port.
When the FEED key is pressed, the printer enters parameter con
fi
guration. Each time the FEED key is pressed,
the parameter will change and the current value will be printed out. Once the desired value has been attained,
hold the FEED key down for at least a second to pass to the next parameter, and so on. Printing out of a new
printer set up report indicates that set up is complete.
1. INSTALLATION AND USE
User Manual
PLUS II 1-13
Summary of Contents for PLUS II
Page 1: ...OEM USER MANUAL PLUS II PLUS II Command Reference DOMC 0009e ...
Page 5: ...1 4 5 PLUS II USB NOTE 1 RESERVED interface only for service use Fig 7 User Manual PLUS II ...
Page 14: ...Blank page INTRODUCTION 6 PLUS II User Manual ...
Page 29: ...2 3 4 Fig 1 20 Fig 1 19 Fig 1 18 1 INSTALLATION AND USE User Manual PLUS II 1 15 ...
Page 32: ...Blank page 1 INSTALLATION AND USE 1 18 PLUS II User Manual ...
Page 50: ...Blank page 3 TECHNICAL SPECIFICATIONS 3 6 PLUS II User Manual ...
Page 63: ......