![Custom Crimp CC440 series Operator'S Manual Download Page 14](http://html.mh-extra.com/html/custom-crimp/cc440-series/cc440-series_operators-manual_2700778014.webp)
CC650
Production / Industrial Hose Crimper
14
AccuCrimp ACT
TM
CONTROL PANEL QUICK START
FULL AUTO MODE
With the crimper in
FULL AUTO
mode additional functions are available:
•
The crimper will cycle automatically from the
CRIMP
button
on the touch screen, the green
CYCLE START
button on the
panel, or the foot switch.
•
To set the position to which the dies will retract, close the
crimper to the desired retract position prior to pressing the
FULL AUTO
button.
Note: The retraction position must be set a minimum amount above the
fi nished crimp diameter or the crimper will not retract. The minimum
retraction diameters are:
CC38 - Crimp Diameter plus 2 mm
CC4-50 - Crimp Diameter plus 2 mm
CC60 - Crimp Diameter plus 3 mm
•
Pressing the
FULL AUTO
button will toggle the crimper into
SEMI-AUTO
mode. In
SEMI-AUTO
mode, pressing the
FOOT SWITCH
or the
CLOSE
button will close the crimper head and releasing it will cause
the head to stop closing. This mode allows the crimper to be jogged into
position allowing more precise positioning of a fi tting in the dies.
Pressing the
SEMI AUTO
button will toggle the crimper back to
FULL
AUTO
mode
In
FULL AUTO
mode pressing the foot switch will start the crimp cycle and
the dies will stop closing when the crimp cycle is complete.
•
The
COUNT
function is activated allowing the operator to
monitor the number of crimps made.
•
A measurement can be required after a preset number of
crimps. See
SET REQUIRED MEASUREMENT
SET REQUIRED MEASUREMENT
•
Press the
PRODUCTION
button.
•
Determine if 1 or 2 crimps will count as a crimp
•
Toggle the
CRIMP ADJUSTMENT REMINDER
to
ON
.
•
Set the
COUNTS BETWEEN CRIMP MEASUREMENTS
to the desired number and press
OK
.
•
At the set interval, the
ADJUST CRIMP
screen will come up
and the operator will be asked to measure the last crimp and
enter a correction if required.