KAD/ADC/129/S2
5
TABLE 4
Balance current outputs
1
PARAMETER
MIN.
TYP.
MAX.
UNITS
CONDITION/DETAILS
Outputs
–
–
4
–
Applied per channel. Connected internally with
corresponding ANALOG(x)- input.
Output current
operating range
-71
–
71
µA
resolution
–
35
–
nA
DC error
error
–
–
2
%FSR
With a constant 175Ω load. The impact of this error on the
channel reading is less than 0.01%FSR (200 times lower
than the error specified here).
drift
–
–
0.15
%FSR
Over temperature.
noise (gain = 1)
–
–
0.5
mV
rms
As measured on analog input.
noise (gain = 10)
–
–
0.05
mV
rms
As measured on analog input.
noise (gain = 100, 1000)
–
–
0.01
mV
rms
As measured on analog input.
Output resistance
–
34.8
–
kΩ
1. The balance line is permanently connected to ANALOG(x)- input. The line is intended for balancing strain gages, so the module
should not be used for asymmetric bridge transducers such as accelerometers or pressure transducers unless sensor re-calibration
is carried out on a channel-by-channel basis.