INSTALLATION
Copyright 2017
3-5
FibreXtreme Hardware Reference
3.6.3 HSSDC2 Copper Cables
The copper media interface on the SL240 cards support shielded cable, terminated with
HSSDC2 style connectors, shown in Figure 3-5. Figure 3-6 displays the HSSDC2 SFP
receptacle used on the SL240 cards. This figure indicates the HSSDC2 contact pin locations
and Table 3-1 contains the pin assignments.
Figure 3-5 HSSDC2 Copper Connector
Figure 3-6 HSSDC2 Receptacle Contact Pin
Locations
Table 3-1 HSSDC2 Receptacle Pin Assignments for SL100
Pin Number
Pin Description
Pin Number
Pin Description
1
Ground
5
Tr
2
Receive -
6
Transmit -
3
R
7
Ground
4
Ground
Table 3-2 HSSDC2 Receptacle Pin Assignments for SL240
Pin Number
Pin Description
1
Ground
2
R
3
Receive -
4
Ground
5
Transmit -
6
Tr
7
Ground
To insure data integrity, take care when selecting the appropriate HSSDC2 cable assembly
for the SL240 application. Application data rate and the presence of equalization circuits
determine length boundaries for HSSDC2 cable assemblies. Applications operating at 2.5
Gbps must use equalized 100 Ohm HSSDC2 cables for cable lengths greater than 5 meters.
However, applications operating at 1.0625 Gbps must use equalized 150 Ohm HSSDC2
cables when cable lengths exceed 20 meters.
NOTE:
The HSSDC2 cables are not interchangeable due to different keying.
Summary of Contents for FHF5-PC4MWB04-00
Page 2: ......
Page 8: ...Copyright 2017 iv FibreXtreme Hardware Reference ...
Page 26: ......
Page 40: ......
Page 48: ...SPECIFICATIONS Copyright 2017 5 8 FibreXtreme Hardware Reference ...
Page 50: ......
Page 68: ......
Page 74: ......
Page 76: ......
Page 78: ......
Page 84: ......
Page 86: ......
Page 96: ......