26 AXN Quick Start Kit User Guide (BK/0045 | 9 Aug. 2021)
3
N
OTE
:
This field is only for editing the IP address of the AXN/BCU/40x in the configuration task file. To change the
IP address of the hardware itself, you must use the IP Address tool (see
“Setting the IP address of the AXN
). Once you have changed the physical IP address, then you edit this field to match.
The port speed of each Ethernet interface can be set to 100BASE-TX or Autonegotiate (recommended setting).
As the AXN/BCU/40x contains an Ethernet switch core, the ability to block traffic coming in on one port from going
out on the other port can be set by enabling the Block Traffic From Other Port setting.
Be default any Ethernet packets generated by the AXN/BCU/40x, or any user modules in the same chassis, are
transmitted out of both ports simultaneously. To restrict chassis traffic to only come out of one of the ports, enable
the Block Traffic From Chassis setting on that port.
The AXN/BCU/40x has a 1 Pulse Per Second TTL output on pin 1 of the top block (see the data sheet). This can
be used for debugging or system commissioning purposes to check the synchronization between multiple chassis.
This output can be enabled by checking the PPS Enable setting.
The AXN/BCU/40x time behavior can be controlled via the time PTPv1 and PTPv2 settings.